Estudio biomecánico comparativo de diferentes técnicas de reparación de las lesiones del flexor digitorum profundus en la zona I de la mano

dc.contributor
Universitat de Barcelona. Departament d'Obstetrícia i Ginecologia, Pediatria i Radiologia i Medicina Física
dc.contributor.author
Ballesteros Betancourt, José Roberto
dc.date.accessioned
2020-11-02T09:06:36Z
dc.date.available
2020-11-02T09:06:36Z
dc.date.issued
2019-10-25
dc.identifier.uri
http://hdl.handle.net/10803/669887
dc.description
Programa de Doctorat Medicina i Recerca Translacional
en_US
dc.description.abstract
INTRODUCCIÓN: La reinserción mediante la técnica de “pullout” de Bunnell modificada se ha considerado la técnica de referencia para la reparación de las lesiones tendinosas del tendón flexor de los dedos en la zona 1. La técnica ideal sería una que no requiriera más incisiones en la pulpa, no creara una conexión externa o dañara la matriz ungueal. Finalmente, si es posible: un procedimiento simple, reproducible y rentable. Con esto en mente, Teo publicó una técnica alternativa para la reinserción del tendón. En este estudio comparamos las propiedades biomecánicas entre la técnica de sutura intraósea de Teo y la técnica de “pullout” de Bunnell modificada en un modelo de cadáver criopreservado después de realizar la reinserción del tendón en la falange. MATERIAL Y MÉTODO: Se asignaron aleatoriamente 36 dedos de cadáveres criopreservados a tres grupos (Teo, Bunnell y grupo de control). Se sometieron a un protocolo de carga cíclica de 2 a 15 N de tensión a 25 mm/min, durante 500 ciclos. La formación de distanciamiento en el sitio de reparación se evaluó cada 100 ciclos y finalmente, las muestras se sometieron a un protocolo de carga hasta el fallo. Se generaron gráficos de desplazamiento de carga para calcular el distanciamiento de la reparación, la fuerza necesaria para generar un distanciamiento de 2 mm, el desplazamiento bajo 20 N de tensión, la fuerza máxima necesaria para el fallo del sistema y la rigidez del sistema. RESULTADOS: El desplazamiento después de 500 cargas cíclicas fue significativamente menor en el grupo de Teo (9.33 mm [SD 1.76]) que en el grupo de Bunnell (13.81 mm [SD 2.08]). El grupo de Teo requirió una tensión de 75.5 N [SD 12.5] para la ruptura del sistema, mientras que el grupo de Bunnell requirió 57.3 N [SD 5.4]. CONCLUSIONES: El grupo Teo presentó un 30% menos de distanciamiento en el protocolo de carga cíclica en comparación con la técnica de “pullout” modificada de Bunnell. Para el fallo de la sutura de Teo, fue necesario aplicar un 31% más de carga en comparación con la técnica de Bunnell.
en_US
dc.description.abstract
BACKGROUND: Surgical repair by fixation into the phalanx is the usual method in the treatment of lesions of the deep flexor tendon in zone 1 of the hand. A wide variety of techniques have been described for the repair, including the Bunnell pullout technique and its modifications; by fixation with one or two suture anchor and combinations of transosseous and anchor sutures. In vitro cyclic testing and a load to failure test were used to compare the repair of a flexor digitorum profundus tendon using the transosseous technique of Teo or a modified Bunnell 2-strand pullout technique using a braided polyester suture. METHODS: Thirty-six fresh-frozen cadaveric fingers were divides randomly into 2 repair groups and a control group: a transosseous technique of Teo with 3-0 braided polyester suture or a modified Bunnell technique with a 3-0 braided polyester suture, and a control group with the flexor intact. After repair, the samples and the control group were loaded cyclically from 2 to 15 N at 25 mm/min, for a total of 500 cycles. Gap formation at the tendon-bone interface and grip-to-grip distance were assessed every 100 cycles. Specimens were tested to failure at the end of 500 cycles. RESULTS: Teo group had approximately a 30% smaller gap every 100 cycles and needed 30% more energy to obtain a 2 mm gap than the modified Bunnell group. Displacement after 500 cyclic loads was significantly lower in the Teo group (9.33 mm [SD 1.76]) than in the Bunnell group (13.81 mm [SD 2.08]) . CONCLUSION: We have found statistical significant biomechanical differences in failure loads and displacements between the two repair technique after rupture of the profundus flexor tendon. For the failure of the Teo suture, it was necessary to apply 31% more load than the Bunnell technique.
en_US
dc.format.extent
236 p.
en_US
dc.format.mimetype
application/pdf
dc.language.iso
spa
en_US
dc.publisher
Universitat de Barcelona
dc.rights.license
ADVERTIMENT. Tots els drets reservats. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.
dc.source
TDX (Tesis Doctorals en Xarxa)
dc.subject
Mecànica humana
en_US
dc.subject
Mecánica humana
en_US
dc.subject
Human mechanics
en_US
dc.subject
Tendons
en_US
dc.subject
Tendones
en_US
dc.subject
Cirurgia ortopèdica
en_US
dc.subject
Cirugía ortopédica
en_US
dc.subject
Orthopedic surgery
en_US
dc.subject
Cirurgia operatòria
en_US
dc.subject
Técnicas quirúrgicas
en_US
dc.subject
Operative surgery
en_US
dc.subject.other
Ciències de la Salut
en_US
dc.title
Estudio biomecánico comparativo de diferentes técnicas de reparación de las lesiones del flexor digitorum profundus en la zona I de la mano
en_US
dc.type
info:eu-repo/semantics/doctoralThesis
dc.type
info:eu-repo/semantics/publishedVersion
dc.subject.udc
617
en_US
dc.contributor.director
Llusá Pérez, Manuel
dc.contributor.director
Combalía Aleu, Andrés
dc.embargo.terms
cap
en_US
dc.rights.accessLevel
info:eu-repo/semantics/openAccess


Documents

JRBB_TESIS.pdf

4.474Mb PDF

This item appears in the following Collection(s)