Estudio comparativo de dos tipos de cotilos troncocónicos roscados


Autor/a

Sánchez Díaz, José-Simón

Director/a

Fernández Sabaté, Alfons

Portabella Blavia, Federico

Data de defensa

2008-04-15

ISBN

9788469156575

Dipòsit Legal

B.42810-2008



Departament/Institut

Universitat de Barcelona. Departament de Ciències Clíniques

Resum

La función de la Cirugía Ortopédica en el ámbito de la patología articular es intentar devolver a la articulación alterada su función. En este ámbito juega un papel importante la sustitución artroplástica.<br/><br/>El aflojamiento aséptico del componente acetabular es la complicación más frecuente e importante que se observa en el seguimiento a largo plazo de las artroplastias de cadera. Este aflojamiento no es exclusivo de las artroplastias cementadas, sino que también existe en las no cementadas, sobretodo en los modelos con cotilos roscados.<br/><br/>A la vista de los resultados clínicos y radiográficos que se obtienen con los cotilos roscados, su utilización es debatida en la actualidad, pues proporcionan una buena estabilidad primaria pero no secundaria, con un elevado índice de aflojamientos.<br/><br/>En el presente trabajo se realiza un análisis completo y exhaustivo sobre las causas y factores implicados en el aflojamiento aséptico de dos modelos de cotilos roscados : cotilo autorroscado de titanio CST y cotilo roscado de Mittelmeier (CM), ambos de Osteo(C). Para ello disponemos de dos series de pacientes, la primera integrada por 102 casos portadores de cotilos CST y la segunda integrada por 100 casos portadores de cotilo tipo Mittelmeier. Se realiza un análisis comparativo desde el punto de vista clínico y radiográfico, además del correspondiente análisis de supervivencia.<br/><br/>La evolución de ambos modelos es relativamente similar, aunque el modelo CST es superior al modelo CM, debido a una mejor supervivencia estadísticamente significativa en función de la estabilidad y al hecho de que el resultado clínico evolutivo se ha mantenido descriptivamente en niveles superiores a lo largo de todo el seguimiento en el modelo CST respecto al modelo CM. No obstante, el elevado índice de aflojamientos observados ha llevado al abandono de su utilización.


<I>The aim of Orthopaedic Surgery in the field of articular pathology is trying to return the damaged joint its function. In this area artroplastic replacement plays an important role.<br/> <br/>The most common and important complication that can be seen in the long-term monitoring of hip arthoplasties is the aseptic loosening of the acetabular component. This relaxation is not unique to the cemented arthroplasties, but also exists in the cementless ones, especially in models with screwed acetabular components. <br/><br/>Given the clinical and radiographic results obtained from screwed acetabular components, its use is currently being debated, since they provide good primary but not secondary stability, showing a high loosening rate. <br/><br/>The following work develops a complete and exhaustive analysis on the causes and factors involved in aseptic loosening of two models of screwed acetabular components: titanium self-screwed acetabular component CST and Mittelmeier screwed acetabular component (CM), both by Osteo(C).<br/><br/>This research has evaluated two sets of patients, the first consisting of 102 individuals carrying CST acetabular components and the second consisting of 100 individuals carrying Mittelmeier-type ones. In addition to the corresponding survival analysis, clinical and radiographic comparative analysis have been conducted. <br/><br/>The evolution of both models is pretty similar, however the CST model has proven superior to the CM model. The reason for that is that the TSA model shows better significative statistically survival rates, related to stability and the fact that the CST evolutive clinical outcome has remained at higher levels than the CM one during all the surveyed period. Nevertheless, the high rate of loosening observed has led to the abandonment of their use. </I>

Paraules clau

Afluixament asèptic; Artoplàsties; Substitució artroplàstica; Cirurgia Ortòpèdica; Malalties articulars

Matèries

617 - Cirurgia. Ortopèdia. Oftalmologia

Àrea de coneixement

Ciències de la Salut

Documents

JSSD_TESIS.pdf

1.677Mb

 

Drets

ADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.