Aturada cardíaca: Optimització de l'administració d'oxigen i resposta fisiològica dels reanimadors a dos minuts ininterromputs de compressions toràciques

dc.contributor
Universitat de Barcelona. Departament de Medicina
dc.contributor.author
Quintana Riera, Salvador
dc.date.accessioned
2011-04-12T13:52:10Z
dc.date.available
2008-01-10
dc.date.issued
2007-03-28
dc.date.submitted
2008-01-10
dc.identifier.isbn
9788469113004
dc.identifier.uri
http://www.tdx.cat/TDX-0110108-125648
dc.identifier.uri
http://hdl.handle.net/10803/2228
dc.description.abstract
1) HIPÒTESIS I OBJECTIUS. Aquesta tesi està basada en dos articles (Quintana S, Martinez Perez J, Alvarez M, Vila JS, Jara F, Nava JM. "Maximum FIO(2) in minimum time depending on the kind of resuscitation bag and oxygen flow". Intensive Care Med. 2004;30(1):155-8. i Quintana S, Sánchez B, Trenado J, Fernández MM, Mestre JV. "The physiological effect on rescuers of doing two minutes of uninterrupted chest compressions". Resuscitation. 2007 Jul;74(1):108-12) que tenen en comú que contemplen aspectes del tractament de l'aturada cardíaca en el Suport Vital Bàsic i Avançat: buscant optimitzar l'aportació d'oxigen durant l'aturada cardiorespiratòria, el primer, avaluant la resposta fisiològica a dos minuts sense interrupcions de compressions toràciques, el segon.<br/><br/>1R. ESTUDI:<br/><br/>"Màxima FiO2 en el mínim temps en funció del tipus de bossa de ressuscitació i el flux d'O2".<br/><br/>Estudi de laboratori per analitzar les FiO2 assolides depenent del tipus de bossa de ressuscitació i els diferents i creixents fluxos d'O2, així com per conèixer el temps que tarda a estabilitzar-se la FiO2.<br/><br/>HIPÒTESI:<br/>En condicions de laboratori, la FiO2 que podem assolir amb una bossa de ressuscitació depèn de molts factors. Quan deixem fixos la freqüència respiratòria i el volum corrent, podem preveure la FiO2 en funció del tipus de bossa de ressuscitació i del flux d'O2 subministrat.<br/><br/>OBJECTIUS:<br/>Objectiu primari: Analitzar els valors de FiO2 assolits en funció del tipus de bossa de ressuscitació i del flux d'O2 administrat, amb freqüència respiratòria i volum corrent fixos.<br/><br/>Objectiu secundari: Estudiar quant temps transcorre fins que s'estabilitza la FiO2.<br/><br/><br/>2N ESTUDI:<br/><br/>"Resposta fisiològica del reanimador d'una aturada cardiorespiratòria a dos minuts de compressions toràciques sense interrupcions."<br/><br/>Estudi de laboratori en el qual, partint de la base que tenim una víctima en aturada cardiorespiratòria ja intubada i amb la via aèria segellada, s'apliquen dos minuts ininterromputs de compressions toràciques.<br/><br/>HIPÒTESI:<br/>La resposta fisiològica del reanimador d'una aturada cardíaca a dos minuts de compressions toràciques sense interrupcions queden dintre d'uns límits perfectament tolerables, tant des del punt de vista objectiu com del subjectiu.<br/><br/>OBJECTIUS:<br/>Objectiu primari: Avaluar la resposta fisiològica del reanimador d'una ACR a dos minuts de compressions toràciques a 100 min-1 sense interrupcions mitjançant l'ànàlisi de la freqüència cardíaca i la SatO2.<br/>Objectius secundaris: Estudiar temps de recuperació després de dos minuts de compressions toràciques ininterrompudes i la resposta subjectiva mitjançant una escala visual analògica.<br/><br/>CONCLUSIONS:<br/><br/>1- Hi ha diferències significatives entre la FiO2 administrada amb els diferents fluxos d'O2 en funció del tipus de bossa de ressuscitació, motiu pel qual s'aconsella:<br/><br/>a) Utilitzar sempre que sigui possible la bossa de ressuscitació del tipus C.<br/><br/>b) El model B, que és el C sense reservori, es comporta administrant la pitjor FiO2. Intentarem evitar-lo, bé muntant el reservori correctament, bé utilitzant el model A.<br/><br/>c) El model A, intermedi continua tenint un paper, ja que és pitjor que el C però millor que aquest quan no està correctament muntat.<br/><br/><br/>2- El flux d'O2 adequat per aconseguir la màxima FiO2 és de 12 litres min-1 per al model C i com a mínim de 20 litres min-1per als altres dos sistemes.<br/><br/>3- El temps que tarda el sistema C per administrar una FiO2 estable és el més curt, inferior al minut, sensiblement inferior al temps que tarda el model B i significativament més curt que el que tarda el model A.<br/><br/>4- El grau de fatiga del reanimador d'una Aturada Cardiorespiratòria com a resultat de dos minuts de compressions toràciques sense interrupcions és perfectament tolerable des del moment que:<br/><br/>a) No hi ha una gran taquicàrdia ni durant els dos minuts de compressions toràciques ni al final i, en tot cas, sempre per sota dels límits d'una prova d'esforç convencional.<br/><br/>b) No es presenta desaturació ni durant ni després de les compressions toràciques.<br/><br/>c) La recuperació després dels dos minuts de compressions toràciques és ràpida i, en tot cas, requereix un interval inferior als dos minuts.<br/><br/>d) La fatiga mesurada amb escala subjectiva és perfectament tolerada per part de la mostra escollida.
cat
dc.description.abstract
<i>"CARDIAC ARREST: OPTIMIZATION OF OXYGEN ADMINISTRATION AND THE PHYSIOLOGICAL RESPONSE OF EMERGENCY CARE PROVIDERS TO APPLYING TWO MINUTES OF UNINTERRUPTED THORACIC COMPRESSION"<br/><br/>TEXT:<br/><br/>Hypothesis and Objectives:<br/><br/>This thesis is based on two articles (Quintana S, Martinez Perez J, Alvarez M, Vila JS, Jara F, Nava JM. "Maximum FIO2 in minimum time depending on the kind of resuscitation bag and oxygen flow". Intensive Care Med. 2004;30(1):155-8. and Quintana S, Sánchez B, Trenado J, Fernández MM, Mestre JV. "The physiological effect on rescuers of doing two minutes of uninterrupted chest compressions". Resuscitation. 2007 Jul;74(1):108-12), which address aspects of treatment responses to cardiac arrest in Basic and Advanced Vital Support. The first article addresses optimizing oxygen supply during cardiorespiratory arrest. The second evaluates the physiological response of the caregiver to two minutes of uninterrupted thoracic compressions.<br/><br/>Study 1:<br/>Maximum FiO2 in the minimum time, as a function of the type of resuscitation bag used and oxygen flow.<br/><br/>A laboratory study to analyze FiO2 achieved depending on the type of resuscitation bag used and different and increasing oxygen flows, as well as the amount of time needed to stabilize FiO2.<br/><br/>HYPOTHESIS:<br/>The FiO2 achieved in a laboratory setting depends on several factors. When respiratory frequency and tidal volume remain fixed, we can predict FiO2 based on the type of resuscitation bag used and oxygen flow administered.<br/><br/>OBJECTIVES:<br/>Primary objective: Analyze FiO2 values achieved as a function of the type of resuscitation bags used and oxygen flows administered, with fixed respiratory frequency and tidal volume.<br/><br/>Secondary objective: Study the amount of time needed to stabilize FiO2.<br/><br/><br/>Study 2:<br/>The physiological response of a caregiver treating cardiac arrest with two minutes of uninterrupted thoracic compressions.<br/><br/>A laboratory study based on the scenario of an intubated patient in cardiorespiratory arrest with a sealed airway, two minutes of uninterrupted thoracic compressions are applied.<br/><br/>HYPOTHESIS:<br/>The physiological response of the caregiver to providing two minutes of uninterrupted thoracic compressions to a patient in cardiac arrest will be within tolerable limits, both objectively and subjectively.<br/><br/>OBJECTIVES:<br/>Primary objective: Evaluate the physiological response of a caregiver to two minutes of uninterrupted thoracic compressions at 100 compressions / minute by analyzing pulse rate and SatO2.<br/>Secondary objective: Study recovery time after the two uninterrupted minutes of thoracic compressions and the caregiver's subjective responses on a visual analogue scale.<br/><br/>CONCLUSIONS<br/><br/>1. There are significant differences between FiO2 administrated with different O2 flows, in function of the type of resuscitation bag used, therefore:<br/>a) The model C bag should be used whenever possible.<br/>b) The model B bag, which is the model C without a reservoir, shows the worst FiO2 results. It should be avoided, either by adding a reservoir correctly, or using the model A bag. <br/>c) The model A, an intermediate type, continues to have a role, since it is generally worse than the model C, but better than the C when incorrectly assembled.<br/><br/>2. Adequate O2 flow for achieving maximum FiO2 is 12 liters/minute for the model C and at least 20 liters/minute for the other two systems. <br/><br/>3. The time it takes to achieve a stable FiO2 with the model C is the shortest, less than a minute, significantly less than the time needed using the model B and less than the time needed with the model A. <br/><br/>4. The grade of fatigue reached by a rescue worker during a cardio-respiratory resuscitation attempt after two minutes of uninterrupted thoracic compressions is perfectly tolerable (and less than that of a conventional stress test). The following observations apply:<br/>a) There is no important tachycardia during the two minutes of thoracic compressions or afterward.<br/>b) There are no desaturation events during or after the thoracic compressions.<br/>c) Recovery after the two minutes of thoracic compressions is rapid and requires less than two minutes.<br/>d) Rescuer fatigue shown on a subjective scale was perfectly tolerated by test subjects. </i>
eng
dc.format.mimetype
application/pdf
dc.language.iso
cat
dc.publisher
Universitat de Barcelona
dc.rights.license
ADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.
dc.source
TDX (Tesis Doctorals en Xarxa)
dc.subject
Suport Vital Avançat
dc.subject
Suport Vital Bàsic
dc.subject
Aturada cardíaca
dc.subject
Compressió toràcica
dc.subject.other
Ciències de la Salut
dc.title
Aturada cardíaca: Optimització de l'administració d'oxigen i resposta fisiològica dels reanimadors a dos minuts ininterromputs de compressions toràciques
dc.type
info:eu-repo/semantics/doctoralThesis
dc.type
info:eu-repo/semantics/publishedVersion
dc.subject.udc
616.1
cat
dc.contributor.authoremail
11145sqr@comb.es
dc.contributor.director
Bergueño Campiñez, María José
dc.contributor.tutor
Garau Alemany, Javier
dc.rights.accessLevel
info:eu-repo/semantics/openAccess
cat
dc.identifier.dl
B.13343-2008


Documentos

SQR_TESI.pdf

1.062Mb PDF

Este ítem aparece en la(s) siguiente(s) colección(ones)