Desarrollo de un estimulador eléctrico integrado implantable para el control de la micción en lesionados medulares

dc.contributor
Universitat Autònoma de Barcelona. Departament d'Enginyeria Electrònica
dc.contributor.author
Uranga del Monte, Aránzazu
dc.date.accessioned
2011-04-12T14:47:24Z
dc.date.available
2001-12-11
dc.date.issued
2001-07-23
dc.date.submitted
2001-12-11
dc.identifier.isbn
8469978179
dc.identifier.uri
http://www.tdx.cat/TDX-1211101-100107
dc.identifier.uri
http://hdl.handle.net/10803/5336
dc.description.abstract
La continencia y la micción dependen de una serie de nervios periféricos que se encuentran situados en la zona sacra de la columna vertebral y regulan la actividad del músculo detrusor ( músculo de la vejiga) y del esfínter. La lesión en la médula altera en mayor o menor grado el control de los músculos y órganos cuyo origen esté por debajo de la zona lesionada. La estimulación eléctrica funcional (FES) permite, mediante la aplicación de estímulos eléctricos, devolver la funcionalidad a dichos órganos.<br/><br/>El objetivo de esta tesis doctoral es el estudio y la realización, mediante circuitería integrada, de un sistema de estimulación eléctrica implantable reconfigurable que permita, mediante estimulación de las raíces sacras en los lesionados medulares, el control de las funciones básicas (micción, defecación y erección). A su vez, se ha implementado un sistema que nos permite verificar el estado del electrodo, una vez que se ha implantado, así como su posible evolución.<br/><br/>A diferencia de los estimuladores existentes, el estimulador implementado nos permite un control exhaustivo de los parámetros de la señal de estimulación, de forma independiente de la distancia entre el implante y la unidad externa. <br/> <br/> A su vez, a lo largo de esta tesis se ha realizado un estudio mediante simulación de la estimulación eléctrica funcional. Se han visto las distintas prestaciones de diversas configuraciones de electrodos. La estimulación eléctrica origina una activación inicial de las fibras de mayor diámetro, antes que las fibras de diámetros menores. Sin embargo, la activación natural implica un orden inverso (primero se activan las fibras de diámetro menor). Esta diferencia da lugar a que, mediante activación eléctrica la graduación de la fuerza sea pobre y se genere una rápida fatiga. Además, existen ciertas aplicaciones específicas (vaciado de la vejiga e intestino...) que requieren la activación de las fibras delgadas sin activación de las fibras de mayor diámetro. Son diversas las técnicas que se están empleando para conseguir esta estimulación selectiva.<br/><br/>En esta tesis se ha estudiado, mediante simulación, la estimulación selectiva de las fibras nerviosas, mediante el empleo del método del bloqueo anódico. Se han generado nuevas señales de estimulación que permiten obtener un ahorro en la carga inyectada durante el estímulo.
spa
dc.description.abstract
Continence and micturition depend on peripheral nerves that are situated in the sacral spinal cord and regulate the activity of the detrusor muscle (bladder muscle) and sphincter. The lesion in the spinal cord modifies the control of muscles and organs which origin is situated under the lesion zone. Functional electrical stimulation (FES) allows, meanwhile the use of electrical stimuli, to recover the functionality. <br/><br/>The goal of this work is the study and development of an electrical stimulation integrated system that allows, meanwhile sacral root stimulation in paraplegic patients, the control of the basic functions (such as micturition, defecation and erection). Moreover, a system that allows to test the electrode and its time evolution, while it is implanted, has been implemented.<br/><br/>By comparing with commercial stimulators, the implemented stimulator allows us to control exactly all the parameters of the stimuli generated, without any modifications due to the external and the implanted unit distance. <br/> <br/>In addition to, along the thesis a computer study of the electrical stimulation has been performed. Different electrode configurations have been analysed. Functional electrical stimulation generates initial large fiber diameter activation, before the small fibers do. However, natural recruitment order is from small to large. This difference cause that, by using electrical stimulation, the strength force be poor and a fast fatigue occurs. Besides, there are several specific applications (bladder and bowel voiding) that need the activation of the small diameter fibers without the large fiber diameter activation. Different techniques are been applied in order to obtain this selective stimulation.<br/><br/>In this thesis, nerve fiber selective stimulation has been studied, by means of simulation. Anodal block technique has been used. New stimulation waveforms have been designed in order to obtain a reduction in the amount of charge injected.
eng
dc.format.mimetype
application/pdf
dc.language.iso
spa
dc.publisher
Universitat Autònoma de Barcelona
dc.rights.license
ADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.
dc.source
TDX (Tesis Doctorals en Xarxa)
dc.subject
Neuroprotesis
dc.subject
CMOS
dc.subject
FES
dc.subject.other
Tecnologies
dc.title
Desarrollo de un estimulador eléctrico integrado implantable para el control de la micción en lesionados medulares
dc.type
info:eu-repo/semantics/doctoralThesis
dc.type
info:eu-repo/semantics/publishedVersion
dc.subject.udc
616.8
cat
dc.contributor.authoremail
arantxa.uranga@uab.es
dc.contributor.director
Barniol Beumala, Núria
dc.rights.accessLevel
info:eu-repo/semantics/openAccess
dc.identifier.dl
B-17112-2002


Documents

maum1de4.pdf

1.100Mb PDF

maum2de4.pdf

1.055Mb PDF

maum3de4.pdf

937.4Kb PDF

maum4de4.pdf

1012.Kb PDF

This item appears in the following Collection(s)