Interactions between titanium surfaces and biological components

dc.contributor
Universitat Politècnica de Catalunya. Departament de Ciència dels Materials i Enginyeria Metal·lúrgica
dc.contributor.author
Pegueroles Neyra, Marta
dc.date.accessioned
2011-04-12T15:04:08Z
dc.date.available
2009-12-24
dc.date.issued
2009-09-16
dc.date.submitted
2009-12-23
dc.identifier.isbn
9788469298466
dc.identifier.uri
http://www.tdx.cat/TDX-1223109-134250
dc.identifier.uri
http://hdl.handle.net/10803/6066
dc.description.abstract
El conocimiento de las interacciones entre célula/proteína/biomaterial es fundamental para la ingeniería de superficies debido a las numerosas aplicaciones biomédicas y biotecnológicas que se están desarrollando así como al éxito clínico que han alcanzado muchos implantes. La respuesta biológica final inducida por los implantes está fuertemente influenciada por las interacciones superficiales entre los componentes biológicos y el material sintético. Las propiedades físicas y químicas de la superficie de un biomaterial, en lugar de las propiedades en su masa, influyen directamente en la capa de proteínas que se adsorben sobre el biomaterial y, como consecuencia de ello, en la respuesta celular a la misma, tanto in vitro como in vivo.<br/><br/>El objetivo de esta tesis doctoral es profundizar en el conocimiento de las interacciones material-biosistema, con el énfasis en el descubrimiento de relaciones entre las propiedades superficiales de las superficies de titanio y su respuesta biológica in vitro.<br/><br/>El titanio comercialmente puro (Ti c.p.) está siendo ampliamente utilizado con éxito durante muchos años como biomaterial para implantes en cirugía ósea. Su excelente biocompatibilidad se basa en sus adecuadas propiedades mecánicas y, con mayor importancia, en su excelente resistencia a la corrosión. Esta última se debe principalmente a la formación espontanea de una fina película de óxido de titanio que le confiere protección natural contra los ataques degradativos. La modificación de la topografía de la superficie del titanio ha sido objeto de investigación en el pasado con el fin de mejorar la osteointegración. El granallado de partículas es una de las tecnologías más utilizadas para conferir rugosidad a las superficies del titanio. La rugosidad óptima y el tipo de partículas abrasivas del granallado para una respuesta óptima in vitro e in vivo fue previamente determinada en nuestro laboratorio. Sin embargo, todavía están por determinar cuáles son las causas últimas que llevan al biomaterial a su exitosa respuesta biológica.<br/><br/>En este trabajo se han estudiado superficies pulidas y rugosas de Ti c.p. obtenidas mediante el granallado con partículas abrasivas de diferente composición química(Al2O3 y SiC) y diferentes tamaños (212-300&#956;m; 425-600&#956;m; 1000-1400&#956;m). La completa caracterización de las propiedades física y química de la superficie, incluyendo la rugosidad, la composición química, la mojabilidad/energía libre y la carga eléctrica de las superficies ensayadas ha llevado a una serie de relevantes conclusiones. Entre ellas, cabe destacar que a) la composición química de las partículas de granallado, así como el método de esterilización fueron los principales factores que influyeron en la mojabilidad y la energía libre superficial de las superficies de titanio estudiadas, b) el método de esterilización cambió en la energía superficial el carácter de donante de electrones de las superficies mediante el cambio de la cantidad y la naturaleza de las sustancias adsorbidas, y c) la composición química de las partículas de granallado no influyó en la carga eléctrica a pH fisiológico ni en el punto isoeléctrico de las superficies.<br/><br/>Un segundo paso consistió en el uso de una microbalanza de cristal de cuarzo con monitorización de la energía de disipación, para el estudio de la cinética de adsorción (cantidad y conformación) y de los procesos de adsorción competitiva de tres proteínas de especial interés en los procesos de curación del hueso - la albúmina de suero bovino (BSA), el fibrinógeno (Fbg), y la fibronectina (Fn)- en sensores lisos recubiertos de TiO2. Se determinaron diferentes modelos de procesos de adsorción con una, dos o múltiples pasos distinguibles en función de las proteínas en solución. La capa adsorbida de BSA mostró los cambios más significativos en sus propiedades mecánicas, de conformación y de incorporación de agua hasta que se alcanzaron las condiciones estables de adsorción de proteínas. La BSA, la más pequeña de las proteínas ensayadas, desplazó la Fn y el Fbg cuando se ensayó en condiciones de la competencia por la adsorción, indicando su mayor afinidad por las superficies de TiO2. También se emplearon técnicas de marcaje fluorescente para el estudio de la adsorción proteica en superficies rugosas granalladas. En este estudio, por un parte, se pudo determinar que la cantidad de Fn y BSA adsorbidas en las superficies granalladas está directamente correlacionada con su energía superficial. Por otra parte, se visualizó la adsorción de fibronectina en solución sobre muestras granalladas rugosas de Ti. La Fn formó un patrón irregular de adsorción con una mayor cantidad de proteína adsorbida en los picos que en los valles de la topografía.<br/><br/>También se evaluó la organización espacial de la matriz extracelular de los osteoblastos, ECM, sobre superficies de Ti lisas y rugosas por medio de la visualización de las fibrillas de Fn teñidas con marcador fluorescente. Las células osteoblásticas depositaron las fibrillas de Fn con un determinado patrón organizado dentro de la matriz total secretada. Aparecen como una película que cubre la parte superior de las diferentes superficies rugosas de titanio. Un resultado relevante es que el espesor de esta capa aumentó con la rugosidad de la topografía subyacente. Sin embargo no más de la mitad de la máxima distancia pico-valle se cubrió con la proteína secretada y/o reorganizada.<br/><br/>Por último, teniendo en cuenta las diferencias en la organización de la ECM y la<br/>adsorción de Fn en las superficies ensayadas de Ti, se realizó un estudio de qRT-PCR para determinar la influencia de las propiedades superficiales del titanio, con y sin preadsorción de Fn, en la respuesta osteoblástica. La expresión génica de la subunidad &#61537;5 de la integrina celular, como marcador de la adhesión celular, se incrementó en las superficies granalladas con SiC en comparación con las granalladas con alúmina. Este resultado fue correlacionado con la mayor cantidad de Fn adsorbida debido a la mayor energía superficial de las superficies granalladas con SiC. El aumento de la rugosidad, así como la presencia de partículas de alúmina en las superficies rugosas incrementó la actividad de ALP y la expresión génica de ALP mRNA por los osteoblastos, y por lo tanto su diferenciación.
spa
dc.description.abstract
The understanding of cell/protein/biomaterial interactions is critical to the engineering of substrates for numerous biomedical and biotechnological applications and to the clinical success of implants. The final biological response induced by implants is strongly influenced by the biological-components/synthetic-material surface interactions. It is well accepted that the physical and chemical surface properties of a biomaterial rather than its bulk properties will influence the protein adlayer and then the cell response to it, both in vitro and in vivo.<br/><br/>The aim of this PhD thesis is to gain an increased understanding of the materialbiosystem interactions, with an emphasis on establishing correlations between surface properties of titanium surfaces and its in vitro biological response.<br/><br/>Commercially pure titanium (c.p. Ti) is being widely and successfully used implant biomaterial in bone surgery over many years. Its excellent biocompatibility is based in its appropriate mechanical properties and, more importantly, in its excellent corrosion resistance, which is mainly due to the presence of a naturally-occurring thin protective titanium oxide film. Modification of titanium surface topography has been a subject of research in the past with the purpose of improving its osseointegration. Grit blasting is one of the most used technologies to roughen titanium surfaces for this purpose. The optimal roughness and type of abrasive blasting-particles for a better in vitro and in vivo response was previously determined in our lab. However, which and how different relevant surface properties of the blasted titanium surfaces induce that optimal biological behavior is still poorly understood.<br/><br/>Smooth/polished and rough c.p. Ti surfaces obtained by blasting with abrasive<br/>particles of different chemical composition (Al2O3 and SiC) and different sizes (212-300&#956;m; 425-600&#956;m; 1000-1400&#956;m) were studied. The comprehensive characterization of physical and chemical surface properties, including roughness, chemical composition, wettability/free energy and electrical charge of the tested surfaces led to a series of relevant conclusions. Among them, it is worth noting that a) the chemical composition of the grit-blasting particles as well as the method of sterilization were found the main factors influencing wettability and surface free energy of the titanium surfaces; b) the sterilization method changed the electron donor character of the surfaces by changing the amount/nature of physisorbed substances on the surfaces, and c) the chemical composition of the blasting particles did not influence on the electrical charge at physiological pH and the isoelectric point of the surfaces.<br/><br/>A second step consisted in the use of a quartz crystal microbalance with monitoring of the energy dissipation to study the adsorption kinetics (amount and conformation) and adsorption competition processes of three proteins of special interest in the healing processes of bone -bovine serum albumin (BSA), fibrinogen (Fbg), and fibronectin (Fn)-on smooth TiO2-coated sensors. Different patterns of adsorption with processes in one, two or multiple distinguishable steps were determined depending of the protein in solution. The BSA adlayers showed the most significant changes in their mechanical properties/conformation/incorporation of water until steady protein-adsorption conditions were reached. BSA, the smallest of the tested proteins, displaced Fn and Fbg when in competition for adsorption, which is an indication of its higher affinity for TiO2 surfaces. Fluorescent labelling techniques where used to study protein adsorption on blasted rough surfaces. Most significantly, the amount of Fn and BSA adsorbed on blasted surfaces was positively correlated with their surface energy. The adsorption of fibronectin from solution on shot-blasted rough titanium surfaces resulted in an irregular pattern of adsorption with a higher amount of protein adsorbed on peaks than on valleys of the topography.<br/><br/>Further, the spatial organization of the osteoblast extracellular matrix, ECM, on smooth and rough Ti surfaces was evaluated by visualizing fluorescently-stained Fn-fibrils. Osteoblast-like cells deposited Fn- fibrils in a specific facet-like pattern that was organized within the secreted total matrix. It appeared as a film overlying the top of the different rough titanium surfaces. Interestingly, the thickness of this layer increased with the roughness of the underlying topography, but no more than half of the total maximum peak-to-alley distance was covered.<br/><br/>Finally, taking into consideration the differences in ECM organization and Fn adsorption on the tested Ti surfaces a qRT-PCR study was carried out to elucidate the influence of titanium surface properties with and without Fn-precoatings on the osteoblast response. The expression of &#61537;5 integrin subunit gene, as a marker for cell adhesion, was increased in SiC-blasted surfaces compared to alumina-blasted surfaces. This was related to the higher amount of adhesive-protein Fn adsorbed caused by the higher surface energy of SiC-blasted surfaces. The increase of roughness as well as the presence of alumina particles on blasted surfaces increased ALP activity and ALP mRNA gene expression by osteoblasts, and so their differentiation.<br/><br/>This research work contribute to increase our knowledge on the interactions taking place at the bio/non-bio interface between different biological components -water, proteins, cells- and materials of clinical relevance, such as rough titanium. The<br/>intertwined effects of the different properties of the synthetic surfaces appear as a challenge to unravel the ultimate causes that determine the fate of cells on synthetic biomaterials.
eng
dc.format.mimetype
application/pdf
dc.language.iso
eng
dc.publisher
Universitat Politècnica de Catalunya
dc.rights.license
ADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.
dc.source
TDX (Tesis Doctorals en Xarxa)
dc.subject
adhesion
dc.subject
QCM-D
dc.subject
differentiation
dc.subject
blasting
dc.subject
roughness
dc.subject
surface energy
dc.subject
interactions
dc.subject
osteoblast-like cells
dc.subject
albumin
dc.subject
extracellular matrix fibronectin
dc.subject
proteins
dc.subject
surfaces
dc.subject
titanium
dc.title
Interactions between titanium surfaces and biological components
dc.type
info:eu-repo/semantics/doctoralThesis
dc.type
info:eu-repo/semantics/publishedVersion
dc.subject.udc
620
cat
dc.contributor.director
Aparicio Bádenas, Conrado
dc.contributor.codirector
Gil Mur, Francesc Xavier
dc.rights.accessLevel
info:eu-repo/semantics/openAccess
dc.identifier.dl
B.10137-2010


Documents

MPN1de2.pdf

5.665Mb PDF

MPN2de2.pdf

5.753Mb PDF