dc.description.abstract
Les malalties infeccioses, en particular les infeccions associades a l'atenció sanitària (IAAS), plantegen importants
reptes per a la salut, ja que augmenten la mortalitat, la morbiditat i els costos sanitaris. Les IAAS afecten milions de
pacients anualment, cosa que emfatitza la necessitat d’implementar mesures efectives de control i prevenció. Aquesta
tesi aborda la necessitat crítica d'un diagnòstic precoç d'infeccions mitjançant el desenvolupament de tecnologies
avançades de biosensors per a la detecció ràpida i precisa d’analits d’interès clínic.
Aquesta investigació es va basar principalment en el desenvolupament d'una plataforma de nanocanals bioinspirada
que utilitza silici porós (pSi) per a aplicacions de biosensat electroquímic. Es va triar el pSi per la seva àmplia
superfície, mida de porus ajustable, biocompatibilitat i facilitat de funcionalització, el que el converteix en un excel·lent
candidat per a plataformes de biosensat. La fabricació del pSi mitjançant anodització electroquímica va permetre un
control precís de les característiques dels porus. L'estabilització i funcionalització de la superfície del pSi van ser
essencials per millorar les seves propietats i prevenir l'oxidació.
ca
dc.description.abstract
Las enfermedades infecciosas, en particular las infecciones asociadas a la atención sanitaria (IAAS), plantean
importantes desafíos para la salud, aumentando la mortalidad, la morbilidad y los costos sanitarios. Las IAAS afectan
a millones de pacientes anualmente, lo que enfatiza la necesidad de implementar medidas efectivas de control y
prevención. Esta tesis aborda la necesidad crítica de un diagnóstico temprano de infecciones mediante el desarrollo
de tecnologías avanzadas de biosensores para la detección rápida y precisa de analitos de interès clínico. Esta
investigación se basa en el desarrollo de una plataforma de nanocanales bioinspirada que utiliza silicio poroso (pSi)
para aplicaciones de biosensado electroquímico. Se eligió el pSi por su amplia superficie, tamaño de poro ajustable,
biocompatibilidad y facilidad de funcionalización, lo que lo convierte en un excelente candidato para plataformas de
biosensado. La fabricación del pSi mediante anodización electroquímica permitió un control preciso de las
características de los poros. La estabilización y funcionalización de la superficie del pSi fueron esenciales para
mejorar sus propiedades y prevenir la oxidación. Se emplearon técnicas como la silanización y la hidrosililación para
introducir grupos funcionales para la inmovilización de bioreceptores.
ca
dc.description.abstract
Infectious diseases, particularly healthcare-associated infections (HAIs), posed significant health challenges,
increasing mortality, morbidity, and healthcare costs. HAIs affected millions of patients annually, emphasizing the need
for effective control and prevention measures. This thesis addressed the critical need for early diagnosis and treatment
guidance of infections by developing advanced biosensing technologies for rapid and precise detection of key analytes
(e.g., miRNA, bacteria, viral biomarker…).
The core focus of this research was the development of a bio-inspired nanochannel platform utilizing porous silicon
(pSi) for electrochemical biosensing applications. PSi was chosen for its high surface area, tunable pore size,
biocompatibility, and ease of functionalization, making it an excellent candidate for biosensing platforms. The primary
focus was on electrochemical etching, which allowed precise control over pore characteristics. Stabilizing and
functionalizing the pSi surface was essential for enhancing its properties and preventing oxidation.
ca
dc.format.extent
218 p.
ca
dc.publisher
Universitat Rovira i Virgili
dc.rights.license
ADVERTIMENT. Tots els drets reservats. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.
ca
dc.source
TDX (Tesis Doctorals en Xarxa)
dc.subject
Materials porosos
ca
dc.subject
Biosensors electroquímics
ca
dc.subject
Estabilització de carboni
ca
dc.subject
Materiales porosos
ca
dc.subject
Biosensores electroquímicos
ca
dc.subject
Estabilización de carbono
ca
dc.subject
Porous materials
ca
dc.subject
Electrochemical biosensors
ca
dc.subject
Carbon-stabilization
ca
dc.subject.other
Ciències
ca
dc.title
Bio-inspired nanochannel platform for the detection of pathogens in healthcare-associated infections (HAIs)
ca
dc.type
info:eu-repo/semantics/doctoralThesis
dc.type
info:eu-repo/semantics/publishedVersion
dc.contributor.director
Prieto Simón, Beatriz
dc.contributor.director
Ceto Alseda, Xavier
dc.embargo.terms
24 mesos
ca
dc.date.embargoEnd
2026-12-02T01:00:00Z
dc.rights.accessLevel
info:eu-repo/semantics/embargoedAccess