dc.contributor
Universitat Internacional de Catalunya. Departament d'Odontologia
dc.contributor.author
Sanz Moliner, Javier Daniel
dc.date.accessioned
2012-08-02T10:53:11Z
dc.date.available
2014-08-03T05:45:05Z
dc.date.issued
2012-07-06
dc.identifier.uri
http://hdl.handle.net/10803/83931
dc.description.abstract
The purpose of this study was to clinically compare the use of a 810 nm diode laser (DL) following modified Widman flap (test sites) to that of modified Widman flap (MWF) alone (control sites). Thirteen patients with periodontal pockets in two different quadrants with at least one tooth exhibiting a pocket depth of >7 millimeters and attachment levels of >7mm were selected. One side was randomly selected to receive MWF and the other to receive a diode laser following MWF. The DL was used to de-epithelialize the inner part of the periodontal flap and photo-biostimulate the surgical area. Probing depth (PD), clinical attachment levels (CAL), plaque index (PI), and gingival index (GI) were evaluated at baseline, 6 weeks and 5 months. Pain scale assessment (PS), pain medication consumption (PM), tissue edema (TE), and tissue color (TC) were evaluated one week following surgery. Treatment differences were analyzed using McNemar’s test, paired t-tests or a Wilcoxon Signed Rank Test. No statistical differences of CAL gain, PD, GI and PI reduction between laser sites and control sites were seen. Statistically significant differences were seen for TE (p=0.041), PM (p<0.001) and PS (p<0.001) favoring test sites. TC did not show a statistically significant difference (p=0.9766). Patients rated the first surgical treatment performed as more painful than the second (p<0.002). The use of a 810 nm diode laser following modified Widman flap provided additional benefits in terms of less edema and post operative pain.
eng
dc.format.extent
129 p.
cat
dc.format.mimetype
application/pdf
dc.publisher
Universitat Internacional de Catalunya
dc.rights.license
L'accés als continguts d'aquesta tesi queda condicionat a l'acceptació de les condicions d'ús establertes per la següent llicència Creative Commons: http://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.rights.uri
http://creativecommons.org/licenses/by-nc-nd/3.0/es/
*
dc.source
TDX (Tesis Doctorals en Xarxa)
dc.subject
Clinical trial
cat
dc.subject
Periodontal surgery
cat
dc.subject
Wound healing
cat
dc.title
A 810 nm Diode Laser following Modified Widman Flap Surgery
cat
dc.type
info:eu-repo/semantics/doctoralThesis
dc.type
info:eu-repo/semantics/publishedVersion
dc.contributor.director
Nart Molina, José
dc.contributor.codirector
Santos Alemany, Antonio
dc.embargo.terms
24 mesos
cat
dc.rights.accessLevel
info:eu-repo/semantics/openAccess
dc.identifier.dl
B. 24447-2012
cat