Desarrollo de nuevas metodologías analíticas para el control de procesos y productos industriales: Aplicación de la Espectroscopia NIR y la Espectrometría de Movilidad Iónica (IMS)

dc.contributor
Universitat Autònoma de Barcelona. Departament de Química
dc.contributor.author
Zamora Zamora, David
dc.date.accessioned
2013-03-05T15:02:37Z
dc.date.available
2013-03-05T15:02:37Z
dc.date.issued
2012-07-13
dc.identifier.isbn
9788449033582
dc.identifier.uri
http://hdl.handle.net/10803/107974
dc.description.abstract
La industria en general, y particularmente la química y la farmacéutica, necesita mejorar la eficiencia de los procesos de producción, para asegurar la obtención de productos con una elevada calidad y a la vez reducir consumos, lo que redundará en una mejora de la productividad. Esta demanda precisa del desarrollo de metodologías analíticas simples, rápidas, fiables y de bajo coste, que puedan ser utilizadas en rutina y por personal poco cualificado, que posibiliten realizar un seguimiento de todo el proceso de producción, y si es necesario aplicar las medidas correctivas necesarias, con el objeto de obtener productos de elevada calidad. Con el objetivo de proporcionar a la industria nuevas metodologías de análisis que permitan cumplir con estos objetivos, en esta tesis se han realizado diversos estudios basados en la espectroscopia NIR y la espectrometría de movilidad iónica (IMS). En el primer estudio de la tesis se ha aplicado la espectroscopia NIR para la monitorización in-line de un proceso de esterificación enzimática de glicerina con ácido esteárico en presencia de una lipasa de Candida Antarctica, mediante la inmersión de una sonda NIR en el reactor. En los diferentes procesos realizados, la reacción enzimática conduce a la formación de diestearato y monoestearato de glicerina; no se observa la formación de triestearato. Se han desarrollado modelos de calibración PLS para cada uno de los componentes, usando los espectros registrado y los valores obtenidos por cromatografía de permeación en gel; los modelos son simples y presentan una correcta capacidad predictiva. Los métodos desarrollados se han aplicado al seguimiento de otros procesos obteniendo resultados que demuestran la utilidad del NIR en la monitorización in-line de la reacción de esterificación enzimática estudiada. El siguiente estudio ha consistido en el desarrollo de un método NIR para la determinación de los componentes de una mezcla adyuvante para un herbicida que se aplica por pulverización de una suspensión. La gran semejanza de los espectros de algunos componentes ha exigido la aplicación de un diseño experimental para la preparación de muestras, que tiene por objeto asegurar la robustez del modelo de calibración. La aplicación de los modelos construidos a muestras de lotes de producción, mostró la buena capacidad predictiva de los modelos construidos y su utilidad para controlar la composición de este tipo de mezclas. En un tercer trabajo se desarrollaron bibliotecas espectrales para la identificación de formulaciones lubricantes, que presentan espectros muy similares. El método desarrollado basado en la construcción de bibliotecas en cascada o sub-bibliotecas permite asegurar la especificidad necesaria para la discriminación entre productos que la biblioteca general identifica ambiguamente. Utilizando criterios de diferenciación más estrictos la biblioteca permite la diferenciación de formulaciones lubricantes que contienen o no aditivos en un porcentaje relativamente pequeño (0.05-0.7%). En este trabajo también se construyeron modelos PLS para la determinación de composición y viscosidad de los lubricantes. En esta tesis se han desarrollado métodos analíticos utilizando la técnica IMS, por primera vez en nuestro grupo de investigación, con el objeto de complementar algunos aspectos analíticos que no se pueden resolver mediante NIR y que son asequibles a la espectrometría de Movilidad Iónica (IMS). Esta es una nueva técnica nueva que ha sido escasamente utilizada en la industria química y farmacéutica. Se han estudiado, desarrollado y validado dos nuevos métodos analíticos, para la determinación de amina residual a lo largo del proceso de fabricación de amidoaminas y fosfolípidos, y otro para la determinación de dos principios activos (en una baja concentración) de un preparado farmacéutico. En ambos casos se han estudiado la influencia de los factores instrumentales en la respuesta IMS y realizando una optimización del método de cuantificación para conseguir la mejor respuesta instrumental y sensibilidad. Se han construido modelos multivariables que permiten la determinación de las especies de interés. Los métodos desarrollados se han aplicado al control analítico de los preparados estudiados.
spa
dc.description.abstract
The industry, and particularly chemistry and pharmaceuticals, needs to improve the efficiency of production processes to ensure obtaining the products in high quality while reducing consumption, what will result in improving productivity. This demand requires the development of analytical methodologies in simple, fast, reliable and low cost manner, which can be used in routine and by unskilled labor, which enable to track the entire production process, and if necessary, apply corrective actions, to obtain high quality products. In order to provide the industry these new methods of analysis to achieve these objectives, in this thesis there have been carried out several studies based on NIR spectroscopy and ion mobility spectrometry (IMS). In the first study of the thesis, NIR spectroscopy has been applied for in-line monitoring of enzymatic esterification process of glycerol with stearic acid in the presence of a lipase from Candida Antarctica, with a NIR immersion probe in the reactor. In the processes performed, the enzymatic reaction leads to the formation of glycol distearate and glycerol monostearate; not being observed the formation of tristearate. It has been developed PLS calibration models for each of the components, using the spectra recorded and the values obtained by gel permeation chromatography; the models were simple and had a correct prediction. The developed methods have been applied to monitoring processes, obtaining results that demonstrate the usefulness of NIR in-line monitoring of the enzymatic esterification reaction studied. The next study involved the development of a NIR method for determining components of a mixture adjuvant in an herbicide product, which was applied for spraying a suspension. The great similarity of the components spectra has required the implementation of an experimental design for sample preparation, which aim is to ensure robustness of the calibration model. The application of the models built to samples of production batches showed good predictive ability of the models constructed, and their utility for checking the composition of such mixtures. In a third work, spectral libraries were developed for the identification of lubricant formulations, which had very similar spectra. The developed method based on the construction of libraries or sub-cascading libraries, ensures the necessary specificity for discrimination between products that were unambiguously identified in the general library. Using more stringent criteria of differentiation, the library allows the differentiation between lubricant formulations which contain or not additives in a relatively small amount (0.05 to 0.7%). In this work, PLS models were also constructed for the determination of composition and viscosity of lubricants. In the present thesis, we have developed analytical methods using IMS technique for the first time in our research group, in order to complement some analytical issues that cannot be resolved by NIR and that are amenable to IMS. This is a new technique that has been rarely used in the chemical and pharmaceutical industries. There have been studied, developed and validated two new analytical methods for determination of residual amine during the manufacturing process of amidoamines and phospholipids, and one for the determination of two active principles ingredients (in low concentration) of a pharmaceutical preparation. In both cases, we have studied the influence of instrumental factors in the IMS response and we have performed an optimization of the quantification method to get the best instrumental response and sensitivity. Multivariate models were constructed which allowed the determination of the species of interest. The developed methods have been applied to analytical control of the preparations studied.
eng
dc.format.extent
225 p.
dc.format.mimetype
application/pdf
dc.language.iso
spa
dc.publisher
Universitat Autònoma de Barcelona
dc.rights.license
ADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.
dc.source
TDX (Tesis Doctorals en Xarxa)
dc.subject
Expectroscopia NIR
dc.subject
Espectroscopia de movilida sónica (IMS)
dc.subject
Control de procesos
dc.subject.other
Ciències Experimentals
dc.title
Desarrollo de nuevas metodologías analíticas para el control de procesos y productos industriales: Aplicación de la Espectroscopia NIR y la Espectrometría de Movilidad Iónica (IMS)
dc.type
info:eu-repo/semantics/doctoralThesis
dc.type
info:eu-repo/semantics/publishedVersion
dc.subject.udc
543
cat
dc.contributor.authoremail
david.zamora@uab.cat
dc.contributor.director
Blanco Romía, Marcelo
dc.embargo.terms
cap
dc.rights.accessLevel
info:eu-repo/semantics/openAccess
dc.identifier.dl
B-7876-2013


Documentos

dzz1de1.pdf

6.494Mb PDF

Este ítem aparece en la(s) siguiente(s) colección(ones)