Desarrollo y caracterización de métodos de separación y preconcentración de Uranio (VI) a nivel de trazas para su efectiva determinación

dc.contributor
Universitat Autònoma de Barcelona. Departament de Química
dc.contributor.author
Candela Soto, Angélica María
dc.date.accessioned
2014-03-05T10:07:20Z
dc.date.available
2015-03-06T06:45:13Z
dc.date.issued
2013-09-13
dc.identifier.isbn
9788449042379
dc.identifier.uri
http://hdl.handle.net/10803/131278
dc.description.abstract
En este estudio, se han desarrollado la separación, preconcentración y determinación de métodos para el U (VI) en niveles de traza. El diseño de sistemas extracción líquido-líquido, para el U (VI) es el primer paso para desarrollar otros sistemas de separación. Para este fin, diferentes agentes extractantes fueron probados, tributil fosfato (TBP), cloruro de trioctilmetil amonio (Aliquat 336) y ácido bis(2-etilhexil) fosfórico (D2EHPA). Entre ellos, el D2EHPA es el agente de extractante más eficaz para el ión uranilo usando las mismas condiciones de trabajo. De esta forma, se desarrolla un diseño de experimentos Doehlert, el cual permite la optimización de las condiciones químicas del sistema de separación líquido-líquido, para la extracción y la recuperación de U (VI). Las condiciones óptimas establecidas por el modelo, y en relación con la concentración del agente extractante y los agentes de recuperación, se denominan Sistema 1 y Sistema 2. Estas condiciones se aplican en la separación y preconcentración de U (VI) por medio de sistemas de membrana. Estos incluyen membranas líquidas de volumen (BLM), líquidas soportadas (SLM), y poliméricas modificadas con D2EHPA (PMM), el cual es el carrier en todos los sistemas de membrana. Por lo tanto, en el caso de las SLM dos tipos de soportes poliméricos son usados, el Fluoruro de Polivinilideno comercial (PVDF) y la Polisulfona (PSf), sintetizada en el laboratorio, así como la PMM. El Sistema 2 y el soporte PVDF muestran una buena eficacia para la separación de iones de uranilo, desde un punto de vista económico (menor cantidad de reactivo y menos tiempo de trabajo, respectivamente). Tanto la membrana comercial como las membranas poliméricas sintetizadas, se caracterizan por diferentes métodos espectroscópicos y de superficie, lo que permite una comparación en la morfología entre ellas, así como la evaluación de su eficacia en la separación y preconcentración del ión de interés. En el caso de la determinación de U (VI) varios métodos se han desarrollado y aplicado, tales como: espectrometría alfa, y espectrometría de masas con plasma acoplado inductivamente (ICP-MS), y la espectroscopia Raman de superficie mejorada (SERS). En esta última, el estudio de la aplicación de diferentes sistemas de nanopartículas como superficies SERS ha sido comprobado. Estas superficies de nanopartículas interactúan adecuadamente con el ión uranilo, permitiendo su determinación. Los diferentes sistemas estudiados como superficies SERS son: nanopartículas de oro (AuNPs), nanopartículas de oro modificadas con ácido aminometil fosfónico (AuNPs-APA), resinas aniónicas modificadas con AuNPs y APA (Resina-AuNPs-APA), espejos de nanopartículas de plata (AgNPs), y nanopartículas de plata sintetizadas en una matriz polimérica funcionalizada, que es la poliéteréter centona sulfonada (SPEEK-AgNPs). Buenas señales se encuentran con SPEEK-AgNPs, y los mejores resultados se obtienen con los espejos de AgNPs.
spa
dc.description.abstract
In this study, separation, preconcentration and determination methods for uranium (VI) in trace levels have been developed. The design of a liquid-liquid extraction system for uranium (VI) is the first step to develop other separation systems. For this purpose, different extracting solutions are checked, i.e. tri-n-butyl phosphate (TBP), methyltrioctylammonium chloride (Aliquat 336), and bis(2-ethylhexyl) phosphoric acid (D2EHPA). Above them, D2EHPA is the most effective extracting agent for uranyl ion working under the same conditions. In this way, a Doehlert experimental design is developed, allowing the optimization of chemical conditions of the liquid-liquid separation system for both, the extraction and the recovery of U (VI). The corresponding optimal chemical values established by the model, and related to the concentration of the extracting agent and the recovery agents, are called System 1 and System 2. These conditions are applied in the separation and preconcentration of U (VI) by means of membrane systems. These include bulk liquid membranes (BLM), supported liquid membranes (SLM), and modified polymeric membranes with D2EHPA (PMM), which is the carrier agent in all the membrane systems. Thus, in the case of the SLM two types of polymeric supports are checked, such as a commercial polyvinylidene fluoride (PVDF) and a homemade polysulfone (PSf), the later synthesized in the laboratory, as well as the PMM. System 2 and PVDF supports show good effectiveness for the uranyl ion separation, also from an economical point of view (lower amount of reactive and less time of working experiments, respectively). In this way the commercial and the homemade polymeric membranes are characterized by different spectroscopic and surface methods, allowing a comparison in morphology between them, as well as evaluating its effectiveness in the separation and preconcentration of the ion of interest. In the case of the determination of uranium (VI) various methods have been developed and applied, such as alpha spectrometry, and inductively coupled plasma mass spectrometry (ICP-MS), and additionally surface enhanced raman spectroscopy (SERS) is also tested. For the later, the study of the application of different nanoparticles systems as SERS surfaces has been checked. This nanoparticle surfaces properly interact with the uranyl ion, allowing its enhanced determination. The different systems studied as SERS surfaces are: gold nanoparticles (AuNPs), gold nanoparticles modified with aminomethyl phosphonic acid (AuNPs-APA), anionic resins modified with AuNPs-APA (Resina-AuNPs-APA), silver nanoparticles mirrors (AgNPs), and silver nanoparticles synthesized in a functionalized polymeric matrix, which is the sulfonated polyetherether ketone (SPEEK-AgNPs). Good signals are found with SPEEK-AgNPs, and the best results are obtained with AgNPs mirrors.
eng
dc.format.extent
305 p.
dc.format.mimetype
application/pdf
dc.language.iso
spa
dc.publisher
Universitat Autònoma de Barcelona
dc.rights.license
ADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.
dc.source
TDX (Tesis Doctorals en Xarxa)
dc.subject
Uranio (VI)
dc.subject
Membranas
dc.subject
Nanoparticulas
dc.subject.other
Ciències Experimentals
dc.title
Desarrollo y caracterización de métodos de separación y preconcentración de Uranio (VI) a nivel de trazas para su efectiva determinación
dc.type
info:eu-repo/semantics/doctoralThesis
dc.type
info:eu-repo/semantics/publishedVersion
dc.subject.udc
543
cat
dc.contributor.authoremail
angelica.candelica@gmail.com
dc.contributor.director
Palet i Ballús, Cristina
dc.embargo.terms
12 mesos
dc.rights.accessLevel
info:eu-repo/semantics/openAccess
dc.identifier.dl
B-7435-2014


Documentos

amcs1de1.pdf

5.769Mb PDF

Este ítem aparece en la(s) siguiente(s) colección(ones)