Medical image registration based on a creaseness measure

dc.contributor
Universitat Autònoma de Barcelona. Departament d'Informàtica
dc.contributor.author
Lloret i Vilallonga, David
dc.date.accessioned
2011-04-12T14:11:32Z
dc.date.available
2003-03-02
dc.date.issued
2002-09-22
dc.date.submitted
2003-03-01
dc.identifier.isbn
8468802255
dc.identifier.uri
http://www.tdx.cat/TDX-0301103-120226
dc.identifier.uri
http://hdl.handle.net/10803/3028
dc.description.abstract
Esta tesis trata de la puesta en correspondencia automática de imágenes médicas. Proponemos un algoritmo genérico, aplicable a imágenes con una característica determinada: que contengan estructuras en forma de valle o de cresta. Estas estructuras es extraen automáticamente mediante un operador diseñador para detectar su forma. Ejemplos de este tipo de estructuras son los huesos en TC y RM, capilares en imágenes oftalmológicas y los sulci en ecografías. Una vez se han extraído éstas, una de las imágenes se transforma iterativamente mediante una aproximación jerárquica hasta que la función que detecta el alineamiento llega a un máximo. <br/><br/>Hemos presentado informes completos del funcionamiento de este algoritmo para varias modalidades y condiciones de adquisición. En primer lugar, lo hemos aplicado a la puesta en correspondencia de TC con RM. Hemos participado en un proyecto para evaluar nuestro algoritmo para un centenar de imágenes, comparándolo con otros métodos, y los resultados, para algunas modalidades, han sido destacados. <br/><br/>Otro campo de aplicación han sido las imágenes oftalmológicas. En esta modalidad, nuestro algoritmo funcionó mejor y más rápido que los algoritmos existentes hasta la fecha, y además ha podido ser aplicado a secuencias largas de imágenes SLO. Ejecutamos pruebas exhaustivas para conseguir una convergencia rápida y segura, lo que hizo posible, en colaboración con otro grupo, construir un primer prototipo real para un hospital.<br/><br/>Finalmente, hemos explorado diferentes problemas de puesta en correspondencia en el área de las ecografías intra-operativas. Después de construir un sistema informático para capturar y localizar las imágenes en tiempo real, empezamos nuestros experimentos con un cerebro humano in vitro. Conseguimos construir un volumen con las imágenes, y alinearlo con una imagen RM del mismo. Además, conseguimos registrar las imágenes individuales de las ecografías con los volúmenes.
spa
dc.description.abstract
This thesis is concerned with the automatic alignment of medical images. We propose a generic algorithm applicable to images having a particular requisite: they must depict crest or valley-like features. These features are extracted automatically by means of a differential operator sensible to these particular shapes. Examples of detectable features are the bone issue in volume CT and MR, the vessels in ophthalmologic images and sulci in ecographies. Once the features have been extracted, one image is iteratively transformed using a hierarchical approach until an alignment assessment function reaches a maximum. <br/>We have made full reports of the performance of this algorithm for several modalities and conditions. Firstly, we have applied it to CT to MR volume image registration. We havee participated in a project to evaluate the accuracy against a golden standard, for a database of about one hundred pairs of images, whose results ranked us to be very accurate for some modality pairs.<br/><br/>A different medical subject was the registration of ophthalmologic images. In this modality, our algorithm worked better and more generally than previous papers in literature, and could be applied also to long sequences of SLO video images. We performed exhaustive tests to permit a fast and robust convergence which contributed, in collaboration with another research group, to set a real medical application already working in a hospital.<br/><br/>Finally, we explored several registration issues in the area of intra-operative ecographies. After designing a system to grab and locate the ecography transducer, we started the experiments with an in vitro human brain. We could compound a volume with the acquired B-frames and register it accurately to an MR volume (3D-3D), and also register each individual B-scan to the corresponding area in the volume (2D-3D). The registration algorithm for the latter case followed the same general scheme as the others.
eng
dc.format.mimetype
application/pdf
dc.language.iso
cat
dc.publisher
Universitat Autònoma de Barcelona
dc.rights.license
ADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.
dc.source
TDX (Tesis Doctorals en Xarxa)
dc.subject
Posada en correspondència
dc.subject
Cresta
dc.subject
Imatges mèdiques
dc.subject.other
Tecnologies
dc.title
Medical image registration based on a creaseness measure
dc.type
info:eu-repo/semantics/doctoralThesis
dc.type
info:eu-repo/semantics/publishedVersion
dc.subject.udc
68
cat
dc.contributor.authoremail
davidllovi@yahoo.es
dc.contributor.director
Serrat Gual, Joan
dc.rights.accessLevel
info:eu-repo/semantics/openAccess
dc.identifier.dl
B.46.455-2002


Documents

dllv01de23.pdf

203.8Kb PDF

dllv02de23.pdf

353.3Kb PDF

dllv03de23.pdf

414.7Kb PDF

dllv04de23.pdf

609.7Kb PDF

dllv05de23.pdf

377.3Kb PDF

dllv06de23.pdf

422.0Kb PDF

dllv07de23.pdf

484.9Kb PDF

dllv08de23.pdf

228.9Kb PDF

dllv09de23.pdf

477.9Kb PDF

dllv10de23.pdf

275.4Kb PDF

dllv11de23.pdf

430.3Kb PDF

dllv12de23.pdf

362.5Kb PDF

dllv13de23.pdf

263.6Kb PDF

dllv14de23.pdf

347.2Kb PDF

dllv15de23.pdf

456.6Kb PDF

dllv16de23.pdf

390.4Kb PDF

dllv17de23.pdf

520.6Kb PDF

dllv18de23.pdf

383.2Kb PDF

dllv19de23.pdf

585.8Kb PDF

dllv20de23.pdf

382.6Kb PDF

dllv21de23.pdf

327.7Kb PDF

dllv22de23.pdf

307.4Kb PDF

dllv23de23.pdf

311.8Kb PDF

This item appears in the following Collection(s)