Estratègies per a la monitorització de plom en mostres medioambientals emprant sensors electroquímics i (micro)sistemes analítics

dc.contributor
Universitat Autònoma de Barcelona. Departament de Química
dc.contributor.author
Arasa Puig, Eva
dc.date.accessioned
2015-09-30T07:09:56Z
dc.date.available
2017-07-12T05:45:10Z
dc.date.issued
2015-07-13
dc.identifier.isbn
9788449054013
cat
dc.identifier.uri
http://hdl.handle.net/10803/310599
dc.description.abstract
El plom s’ha emprat per a múltiples propòsits durant segles (canalitzacions d’aigua, pintures, bateries, etc.). Actualment, degut a la seva toxicitat i al seu caràcter bioacumulatiu, el seu ús es troba en recessió. No obstant, degut a la seva gran persistència en el medi, aquest encara es pot trobar en quantitats apreciables. La present tesi té com a objectiu principal proporcionar la informació i/o les eines necessàries per tal de conèixer si es compleix amb la legislació vigent referent a la concentració de plom en diferents medis. Aquesta tesi es divideix en dos blocs principals. Al primer bloc es monitoritza la contaminació per plom en l’aigua de consum i en sòls emprant bàsicament les tècniques analítiques clàssiques. La contaminació de l’aigua per plom és una problemàtica existent encara en algunes llars degut a l’existència de canonades de plom com a sistema de distribució domiciliaria d’aigua. En aquesta tesi, i sota un conveni de col·laboració amb l’empresa Societat d’Aigües de Barcelona i Adasa Sistemas, es dissenya i optimitza un sistema automàtic emprant l’extracció en fase sòlida i es proposa un protocol de mostreig per avaluar la ingesta de plom per l’aigua de consum seguint els requeriments de la directiva 98/83/CE. Per altre banda, s’avalua la lixiviació del plom en una canonada nova per a estudiar la ingesta de plom que es va fer en un passat per aquesta via. Una breu introducció com la descripció del desenvolupament, la caracterització i la validació de l’equip es presenten en el capítol 3. La contaminació, aquest cop en el sòl, es presenta en zones properes a la indústria metal·lúrgica. Aquesta situació queda exemplificada en aquesta tesi en el cas de la ciutat de Torreón (Mèxic). Així, en el marc d’un conveni de col·laboració amb l’empresa Met-Mex Peñoles, es monitoritza de forma periòdica (2000-2013) aquesta zona i s’avaluen les accions dutes a terme per l’empresa per tal de minimitzar les fuites fugitives i remeiar la zona afectada. La informació relativa a aquest estudi es troba al capítol 4. Degut als inconvenients (retràs en la informació, cost econòmic elevat, només operatives en ambients controlats) que presenten les tècniques analítiques clàssiques alhora de satisfer la gran demanda d’informació que seria desitjable per a la monitorització ambiental, l’objectiu del segon bloc es buscar alternatives que solucionin/minimitzen aquests inconvenients. Així, es desenvolupen sistemes de cribatge emprant sensors electroquímics (potenciomètrics i voltamperomètrics) com a sistemes de detecció tot aprofitant les avantatges que proporcionen les noves tecnologies de miniaturització. Aquests sistemes s’han desenvolupat per a ser operatius tant en condicions de flux continu com en condicions discretes (batch). Per aconseguir aquest objectiu, al capítol 5 s’avaluen diferents elèctrodes selectius de plom (comercials, sinteritzats en el Grup de Recerca), diferents transductors conductors sòlids compatibles amb la tecnologia de microfabricació LTCC (serigrafiats, modificats sota diferents condicions d’electrodeposició) i s’optimitza la configuració de la cel·la de detecció per a microsistemes de flux. Al capítol 6 s’avaluen diferents materials d’elèctrodes, alguns d’ells obtinguts per tecnologia microelectrònica, com a sensors voltamperomètrics per a la determinació de plom.
cat
dc.description.abstract
Lead has been used for multiple purposes during centuries (water pipes, paint, batteries, etc.). Currently, due to their toxicity and their bioaccumulative nature, its use is in recession. However, due to its high persistence in the environment, it can still be found in significant amounts in the environment and water sources. The main objective of the present work is to provide tools and/or information necessary to ascertain whether the legislation relating to the concentration of lead in different media is complied. This thesis is divided into two main parts. The first is the monitoring of lead contamination in drinking water and soils, basically using classical analytical techniques. Water pollution by lead is a problem that still exists in some households due to the presence of old lead pipes as domiciliary water distribution system. In this thesis, and under a contract agreement with the companies Societat d’Aigües de Barcelona and Adasa Sistemas, an automated system based on solid phase extraction is designed and optimized and a protocol to assess the sampling intake of lead for drinking water is proposed, following the requirements of Directive 98/83/EC. On the other hand, in order to assess the ingestion of lead during the use of a pipe, a study of the lead leaching of a new lead pipe has been done. A brief introduction on this field and the description of the development, characterization and validation of the equipment are presented in Chapter 3. On the other hand, soil pollution usually appears in areas close to metallurgical industry. This situation is exemplified in this thesis in the case of the city of Torreon (Mexico). Thus, in the framework of a cooperation agreement with the company Met-Mex Peñoles, the area near the company is monitored periodically during years (2000-2013) in order to evaluate the actions taken by the company to minimize fugitive emissions and leaks and to remediate the affected area. The information on this study can be found in Chapter 4. Due to the problems (information delay, high cost, and operability only in controlled environments) that classical analytical techniques present to meet the desired high information demands for environmental monitoring, the main goal of the second part of this thesis is focused into finding alternatives to solve/minimize these drawbacks. Thus, screening systems have been developed using electrochemical sensors (potentiometric and voltammetric) as detection systems, while taking advantage of the features that miniaturization technologies can offer. These systems have been developed to operate in both continuous flow and discrete (batch) conditions. To achieve this goal, different selective lead electrodes (commercial and synthesized in the GSB research group) as well as various solid conductor transducers, compatible with the microfabrication technology and the LTCC technology (screen printed, modified under different electroplating conditions) have been evaluated. Moreover, the configuration of the detection cell in microfluidic systems has been optimized. All this information is detailed in Chapter 5. After that, different electrode materials, some of them obtained by microelectronics (for instance voltammetric sensors) have been tested for lead determination. All this work is described in Chapter 6.
eng
dc.format.extent
504 p.
cat
dc.format.mimetype
application/pdf
dc.language.iso
cat
cat
dc.publisher
Universitat Autònoma de Barcelona
dc.rights.license
ADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.
dc.source
TDX (Tesis Doctorals en Xarxa)
dc.subject
Monitorització mediambiental
cat
dc.subject
Monitorización medioambienta
cat
dc.subject
Environmental monitoring
cat
dc.subject
Sensors electroquímics
cat
dc.subject
Sensores electroquimicos
cat
dc.subject
Electrochemical sensors
cat
dc.subject
(Micro)sistemes analítics
cat
dc.subject
(Micro)sistemas analíticos
cat
dc.subject
Analytical (micro)systems
cat
dc.subject.other
Ciències Experimentals
cat
dc.title
Estratègies per a la monitorització de plom en mostres medioambientals emprant sensors electroquímics i (micro)sistemes analítics
cat
dc.type
info:eu-repo/semantics/doctoralThesis
dc.type
info:eu-repo/semantics/publishedVersion
dc.subject.udc
543
cat
dc.contributor.authoremail
eva.arasa@uab.es
cat
dc.contributor.director
Alonso Chamarro, Julián
dc.embargo.terms
24 mesos
cat
dc.rights.accessLevel
info:eu-repo/semantics/openAccess


Documents

eap1de1.pdf

7.804Mb PDF

This item appears in the following Collection(s)