dc.description.abstract
Obtener una alta calidad en la industria farmacéutica es un reto constante que
requiere un estricto control y supervisión de los productos manufacturados. La
tecnología analítica de procesos (PAT, Process Analytical Technology) propone que
esto puede lograrse de una manera óptima y sistematizada mediante el control de
calidad en diferentes etapas de manufactura (materias primas, intermedios y
producto acabado).
La simplicidad y rapidez de la espectroscopía de infrarrojo cercano (NIRS, Near
Infrared Spectroscopy) junto con el análisis quimiométrico de datos multivariables ha
demostrado su eficacia para la determinación de propiedades físicas y composición
química de productos farmacéuticos, y su uso en esta industria se ha incrementado
considerablemente en los últimos años.
El objetivo de esta Tesis es el desarrollo de métodos NIR para el control de calidad en
la industria farmacéutica. Para ello, se propusieron y optimizaron nuevas estrategias
de diseño y selección del conjunto de calibración y la mejora de las estrategias de
modelado NIR, basado en conceptos como el conocimiento del producto y
comprensión del proceso de acuerdo con la filosofía de trabajo PAT.
La Tesis consiste en tres casos de estudio de diferentes formulaciones farmacéuticas
sólidas. En el primer estudio se evalúan diferentes metodologías para la construcción
del conjunto de calibración, y también se propone un nuevo modo de cálculo y adición
del espectro. Se evaluó la idoneidad de dichas estrategias para la cuantificación de un
principio activo (API, active pharmaceutical ingredient) presente a baja concentración
(10 miligramos por gramo). Los principales resultados mostraron la eficacia de esta
nueva metodología para el control de calidad de un granulado farmacéutico (producto
acabado), y demostró una sobresaliente capacidad en términos de robustez y
simplicidad experimental en comparación con otras estrategias evaluadas.
El segundo estudio consiste en la optimización del proceso de selección de factores
relevantes en la implementación de una metodología novedosa para la preparación del conjunto de calibración. Para ello se calcularon modelos para el control de calidad
de una formulación en sus tres etapas de fabricación: polvo, núcleos y comprimidos
recubiertos. De los resultados obtenidos en este estudio se confirmó la idoneidad del
concepto de espacio del modelo definido por los estadísticos T2 Hotelling y residuales
Q para la identificación de muestra anómalas (dentro/fuera del espacio), y para la
selección objetiva de los factores a utilizar en la construcción conjunto de calibración.
También se corroboró la eficacia del método NIR propuesto para el control de calidad
en variadas etapas del proceso.
El tercer caso de estudio aborda una problemática en la industria farmacéutica que
concierne al análisis NIR de muestras sólidas con tendencia a la segregación de sus
componentes. En este estudio se evalúa el área efectiva de escaneado espectral y la
representatividad de la porción de muestra analizada. También se propone una
alternativa eficaz de análisis por NIR para este tipo de muestras basada en la
adquisición de espectros de muestras en movimiento. Los resultados obtenidos en
este trabajo confirman la influencia del área escaneada con la representatividad de la
muestra analizada y esto, a su vez, a la capacidad predictiva de los modelos de
calibración. Este estudio resalta la importancia de la optimización del área de
escaneado de superficie previo cálculo del modelo, ya que se confirmó como estos
factores influyen en los estadísticos de predicción de los métodos NIR propuestos.
Este trabajo presenta una alternativa eficaz para el control de calidad de muestras
heterogéneas o con tendencia a segregación.
Los métodos propuestos en cada uno de los casos de estudios fueron evaluados de
acuerdo con las directrices internacionales y europeas, y representan una
contribución a la iniciativa PAT y el desarrollo de metodologías NIR en base a su
mejora mediante un mejor conocimiento del producto y una mayor comprensión del
proceso.
spa
dc.description.abstract
Accomplish high quality in the pharmaceutical industry is a constant challenge that
require strict control and supervision not only from final products but also from all
manufacturing steps according to process analytic technologies (PAT) initiative.
In recent years, the simplicity and expeditiousness of near infrared spectroscopy
(NIRS) together with chemometrics data analysis have substantially fostered its use
for the determination of pharmaceutical´s physical and chemical properties.
The subject of this thesis is the development of NIR methodologies useful for the
quality control for the pharmaceutical industry, proposing and optimizing mainly new
strategies for the selection and design of the calibration set and improving NIR
methodologies based on product knowledge and process understanding.
The thesis consists in three cases of study where different solid pharmaceutical
formulations were evaluated. In the first study a new methodology for constructing
the calibration set is proposed and its suitability for quantifying an API present in low
concentration (10 mg.g-1) was evaluated by comparison with two methodologies
broadly known. The main results showed the efficiency and suitability of the
calculation ad addition of process spectra methodology for the quality control of a
pharmaceutical granulate (final product). This methodology showed an outstanding
performance in terms of robustness and operational simplicity in comparison with the
other evaluated strategies.
The second study consists in the optimization of a novel methodology through the
incorporation of statistical parameters for the selection of important factors used, and
three calibration models were calculated for the quality control of a formulation in its
three manufacturing steps: powder, cores and coated tablets. Based on the results
obtained with this study the model space concept was established defined by
Hotelling’s T2and Q-residuals statistics for outlier identification – inside/outside the
defined space – in order to select objectively the factors to be used in the calibration set construction. Also the efficacy of the proposed methodology for stepwise
pharmaceutical quality control was confirmed. This work represented a contribution
for the field as a guideline for the implementation of this easy and fast methodology in
the pharma industry.
A third study case addresses a concern in the pharmaceutical industry regarding
samples with tendency of segregation and its analysis by using NIR spectroscopy. In
this study the effective scanned area and the sample representativeness is evaluated,
and an effective alternative based on spectra acquisition on moving samples is
proposed. The results obtained in this work confirmed the influence of the scanned
area with the representativeness of the analyzed sample and this, in turn, the
performance of the calculated calibration models. This study highlights the
importance of the optimization of the surface scanned area since the quality of the
methodologies to be developed depends strongly on this factor. This work presents an
effective alternative for quality control on samples with tendency to segregate.
The proposed methods were evaluated according to the European and international
guidelines and represent a contribution to the PAT initiative and the development of
NIR methodologies based on its improvement by a better product knowledge and
process understanding.
eng
dc.format.extent
168 p.
cat
dc.format.mimetype
application/pdf
dc.publisher
Universitat Autònoma de Barcelona
dc.rights.license
L'accés als continguts d'aquesta tesi queda condicionat a l'acceptació de les condicions d'ús establertes per la següent llicència Creative Commons: http://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.rights.uri
http://creativecommons.org/licenses/by-nc-nd/3.0/es/
*
dc.source
TDX (Tesis Doctorals en Xarxa)
dc.subject
Quimometria
cat
dc.subject
Chemometrics
cat
dc.subject
Quimiometría
cat
dc.subject
Industria farmaceutica
cat
dc.subject
Pharmaceutical industry
cat
dc.subject
Industria farmaceutica
cat
dc.subject.other
Ciències Experimentals
cat
dc.title
Development of new analytical methods using Near Infrared and Chemometrics for pharmaceutical quality control: Enhancement of modelling strategies towards a better product understanding
cat
dc.type
info:eu-repo/semantics/doctoralThesis
dc.type
info:eu-repo/semantics/publishedVersion
dc.contributor.authoremail
vanessa.cardenase@gmail.com
cat
dc.contributor.director
Blanco Romía, Marcelo
dc.contributor.director
Alcalà Bernàrdez, Manel
dc.rights.accessLevel
info:eu-repo/semantics/openAccess