Development of electrochemical (bio)sensors and microanalytical systems. Application to the wine industry

dc.contributor
Universitat Autònoma de Barcelona. Departament de Química
dc.contributor.author
Giménez Gómez, Pablo
dc.date.accessioned
2017-09-12T13:22:01Z
dc.date.available
2017-09-12T13:22:01Z
dc.date.issued
2017-06-28
dc.identifier.isbn
9788449071843
en_US
dc.identifier.uri
http://hdl.handle.net/10803/405524
dc.description.abstract
El mercado creciente de la industria del vino necesita garantizar los estándares de calidad y la protección del consumidor mediante el seguimiento de varios parámetros a lo largo del proceso de elaboración del vino. La aplicación de los (bio)sensores electroquímicos aporta una respuesta rápida, una miniaturización a bajo coste y una fácil implementación para la detección in-situ. Los (bio)sensores son una buena alternativa a los tediosos métodos tradicionales aplicados en laboratorios especializados. En esta tesis se presenta el desarrollo de (bio)sensores electroquímicos fabricados con tecnología microelectrónica y su implementación en sistemas de flujo fabricados con técnicas de prototipado rápido, para la monitorización de parámetros químicos de interés en la industria vinícola. Como (bio)sensores se han utilizado Transistores de Efecto Campo Sensibles a Iones (ISFETs) y microelectrodos de platino/Oro como biosensores bienzimáticos amperométricos. Esta Tesis es el resultado de cinco artículos publicados en revistas internacionales y contiene cinco capítulos. En la Introducción se describe el estado del arte de los ISFETs y los biosensores amperométricos. Se explican los métodos para la inmovilización de enzimas en sensores y en particular los basados en polímeros de polipirrol. Finalmente, se revisa la implementación de sensores electroquímicos en sistemas lenguas electrónicos y en sistemas analíticos de flujo. En el capítulo de Experimental se describe en detalle la fabricación de todos los (bio)sensores y sistemas de flujo utilizados, así como su metodología de caracterización (incluyendo las mediciones en vino). En el capítulo de Resultados y Discusión, se describen los objetivos alcanzados. Se aplicaron ISFETs para determinar SO2 libre y total en vino. Se propuso un sistema de flujo sencillo basado en la separación del analito de la muestra con una membrana de difusión de gases y su posterior detección con un ISFET de pH. El sistema se validó con 70 vinos y dos métodos estándar. Se desarrolló un sistema de flujo más compacto para la determinación simultánea de SO2 libre y ácido acético. Este sistema de flujo permitió integrar en un solo módulo la membrana de difusión de gas, el ISFET y el electrodo de referencia, cumpliendo los requisitos de medición en barricas. Este sistema se evaluó comparando los resultados en vinos con los obtenidos con los métodos oficiales. Por otro lado, se desarrollaron biosensores enzimáticos amperométricos para determinar L-lactato y L-malato. Se modificaron la superficie metálica de los microelectrodos con membranas de polipirrol sintetizadas electroquímicamente, permitiendo el atrapamiento de los reactivos implicados en la reacción bienzimática. Los biosensores mostraron una excelente estabilidad de trabajo, conservando más del 90% de su sensibilidad tras 40 días. Esto permitió su aplicación para monitorizar la fermentación maloláctica de vinos, mostrando resultados análogos a los obtenidos con el método estándar. Tras optimizar ambos biosensores amperométricos, se diseñó y fabricó un nuevo chip de silicio para determinar simultáneamente ambos parámetros. Este chip fué montado en un sistema de flujo de pequeño tamaño para el análisis en línea de L-lactato y L-malato. El sistema fue evaluado con éxito con muestras de vino. También se describió la aplicación de una lengua electrónica portátil basada en microsensores para el análisis de Cava. El sistema contenía una serie de microsensores formados por seis ISFETs sensibles al pH, Na+, K+, Ca2+, Cl- y CO32-, un sensor de conductividad, un sensor de potencial redox y dos microelectrodos amperométricos de oro. Este sistema, combinado con herramientas de análisis quimiométricas, se aplicó al análisis de 78 muestras de Cava, clasificándolas según el tiempo de envejecimiento (utilizando un Análisis Discriminante Lineal) y cuantificando la acidez total, el pH, el grado alcohólico volumétrico, el potasio, la conductividad, el glicerol y el metanol (utilizando regresiones de mínimos cuadrados parciales).
en_US
dc.description.abstract
The growing wine market needs to guarantee quality standards and the consumer protection by monitoring several parameters along the winemaking processes. Application of electrochemical (bio)sensors in this field is promising due to their simplicity, fast response, low-cost and easy miniaturization for on-site detection. Besides, biosensors are a good alternative to expensive and tedious traditional methods applied in specialized laboratories. In this Thesis, the development of electrochemical (bio)sensors fabricated with microelectronic technology and its implementation in fast-prototyped flow systems for the monitoring of chemical parameters of interest in the winemaking industry, is reported. Ion-Sensitive-Field-Effect-Transistors (ISFETs) and Platinumt/Gold microelectrodes as amperometric bienzymatic biosensors, have been used. This manuscript is the result of five papers published in international journals and contains five chapters. In the introduction chapter, the theoretical principles and the state-of-the-art of the ISFETs and amperometric biosensors are described. The methods for enzyme immobilization on sensors and in particular those based on polypyrrole polymers are explained. Finally, the implementation of electrochemical sensors in electronic tongues and in flow analytical systems is reviewed. In the experimental chapter is described in detail the fabrication of all the (bio)sensors and microanalytical flow systems used and their characterization methodology, including the procedure for wine measurements. Regarding Results and discussion chapter, describe the specific goals achieved. Firstly, ISFETs were applied for the determination of free and total sulfur dioxide in wine samples. A simple microanalytical flow system based on the separation of the analyte from the sample with a gas diffusion membrane and its indirect detection with a pH-ISFET, was proposed. The validation of the system was carried out using wine samples and two standard methods, the Ripper and the Paul method. The good results obtained with this system encouraged us to develop a more compact flow system for the simultaneous determination of free sulfur dioxide and acetic acid. This small-sized microanalytical flow system integrated in only one module the gas-diffusion membrane, the ISFET and the reference electrode, accomplishing the requirements of measurement in a barrel. This system was also evaluated by comparing the results obtained for wine samples with those obtained with the official methods. On the other hand, the development of amperometric enzymatic biosensors for the determination of L-lactate and L-malate was carried out. They were fabricated by modifying the metal surface of the microelectrodes with polymeric membranes of polypyrrole synthetized electrochemically. These three-dimensional matrices allowed the entrapment of the biochemical reagents involved in the bienzymatic reaction. The amperometric biosensors showed an excellent working stability, retaining more than 90 % of its original sensitivity after 40 days. This allowed their application to monitor the malolactic fermentation of red wines, showing a good agreement with the standard colorimetric method. Once both amperometric biosensors were optimized, a new silicon-chip was designed and fabricated for simultaneous determination of both parameters. This chip was assembled in a small-size flow system for on-line analysis of L-lactate and L-malate. Finally, the microanalytical flow system was successfully evaluated with wine samples. The application of a portable electronic tongue based on microsensors for the analysis of Cava wine was also described. The system contained an array of microsensors formed by six ISFETs sensitive to pH, Na+, K+, Ca2+, Cl− and CO32-, one conductivity sensor, one redox potential sensor and two amperometric gold microelectrodes. This system, combined with chemometric tools, was applied to the analysis of 78 Cava wine samples, classifying them according to the ageing time (using a Linear Discriminant Analysis) and quantifying the total acidity, pH, volumetric alcoholic degree, potassium, conductivity, glycerol and methanol parameters (using Partial Least Squares regressions).
en_US
dc.format.extent
237 p.
en_US
dc.format.mimetype
application/pdf
dc.language.iso
eng
en_US
dc.publisher
Universitat Autònoma de Barcelona
dc.rights.license
ADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.
dc.source
TDX (Tesis Doctorals en Xarxa)
dc.subject
(bio)Sensors electroquímics
en_US
dc.subject
(bio)Sensores electroquímicos
en_US
dc.subject
Electrochemical (bio)snesors
en_US
dc.subject
Sistemes de microanàlisi
en_US
dc.subject
Sistemas microanaliticos
en_US
dc.subject
Microanalytical systems
en_US
dc.subject
Indústria del vi
en_US
dc.subject
Industria del vino
en_US
dc.subject
Wine industry
en_US
dc.subject.other
Ciències Experimentals
en_US
dc.title
Development of electrochemical (bio)sensors and microanalytical systems. Application to the wine industry
en_US
dc.type
info:eu-repo/semantics/doctoralThesis
dc.type
info:eu-repo/semantics/publishedVersion
dc.subject.udc
543
en_US
dc.contributor.authoremail
pablo.gimenezgomez@gmail.com
en_US
dc.contributor.director
Jiménez Jorquera, Cecilia
dc.contributor.director
Gutiérrez Capitán, Manuel
dc.contributor.tutor
Gallardo García, Iluminada
dc.embargo.terms
cap
en_US
dc.rights.accessLevel
info:eu-repo/semantics/openAccess


Documents

pgg1de1.pdf

6.789Mb PDF

Aquest element apareix en la col·lecció o col·leccions següent(s)