Uso de biópticos (ICL y Lasik) para la corrección de la alta miopía

dc.contributor
Universitat Autònoma de Barcelona. Departament de Cirurgia
dc.contributor.author
Puig Galy, Javier José
dc.date.accessioned
2011-04-12T14:29:52Z
dc.date.available
2001-07-16
dc.date.issued
2001-05-16
dc.date.submitted
2001-07-16
dc.identifier.isbn
8469977601
dc.identifier.uri
http://www.tdx.cat/TDX-0716101-095311
dc.identifier.uri
http://hdl.handle.net/10803/4233
dc.description.abstract
OBJETIVOS: <br/>Determinar la eficacia, predictibilidad, estabilidad y seguridad de la cirugía refractiva mediante "Biópticos" (combinación del implante de una lente fáquica de cámara posterior y láser in situ queratomileusis) en pacientes afectos de altas miopías.<br/>Describir el procedimiento quirúrgico y mostrar los resultados visuales y refractivos del mismo.<br/><br/>MATERIAL Y MÉTODOS:<br/>Hemos analizado 102 ojos de 63 pacientes afectos de alta miopía, intervenidos mediante el implante de una lente fáquica de cámara posterior tipo ICLTM y láser in situ queratomileusis (Lasik).<br/>El seguimiento postoperatorio medio fue de 19 meses (rango: 12-36 meses).<br/><br/>RESULTADOS:<br/>El equivalente esférico medio preoperatorio fue de -18,20 ± 4,21 D., con un astigmatismo medio asociado de -1,87 ± 1,57 D. La media aritmética del equivalente esférico tras implantar la lente fáquica y antes de realizar el Lasik fue de -2,59 ± 2,04 D. El equivalente esférico medio tras el procedimiento Bióptico completo resultó ser de -0,28 ± 0,33 D., con un cilindro medio de -0,53 ± 0,35 D.<br/>El 100% de los pacientes se encontraban postoperatoriamente en el rango de ± 1,00 D. respecto a la emetropía, mientras el 95,09% lo hacían en el rango de ± 0,50 D.<br/>Las refracciones postoperatorias se mantuvieron estables durante los sucesivos controles, sin cambios estadísticamente significativos.<br/>La agudeza visual sin corrección mejoró en todos los casos. La agudeza visual corregida se mantuvo igual o mejoró postoperatoriamente en todos los casos excepto en dos. La media de ganancia de agudeza visual corregida postoperatoria fue de dos líneas de Snellen.<br/>Todos los pacientes se mostraron muy satisfechos con los resultados obtenidos.<br/><br/>DISCUSIÓN:<br/>El uso combinado de lentes fáquicas de cámara posterior tipo ICLTM y Láser in situ queratomileusis (Lasik) constituye un método efectivo y predecible para corregir la alta miopía.<br/>Es frecuente la mejoría postoperatoria de la agudeza visual corregida de estos pacientes. Los resultados muestran una considerable seguridad del procedimiento a corto y medio plazo, así como una gran estabilidad refractiva.
spa
dc.description.abstract
PURPOSE: <br/>To determine the efficacy, predictability, stability and safety of "Bioptics" refractive surgery (combined posterior chamber phakic intraocular lens implantation and laser in situ keratomileusis) in eyes with extreme myopia. <br/>To report the technique and to assess the results (refraction and visual acuity) of this surgical procedure.<br/><br/>MATERIAL AND METHODS: <br/>We analyzed the results of 102 eyes that received a posterior chamber hydrogel-collagen plate phakic IOL (ICLTM) and also underwent secondary Lasik for the correction of extreme myopia. <br/>Mean follow-up was 19 months after the Lasik procedure (range 12 to 36 months).<br/><br/>RESULTS: <br/>Mean preoperative spherical equivalent refraction was -18,20 ± 4,21 D., and mean refractive cylinder was -1,87 ± 1,57 D. Mean spherical equivalent refraction after IOL implantation and before Lasik was -2,59 ± 2,04 D. Mean postoperative spherical equivalent refraction one year after the Lasik portion of the double Bioptics procedure was -0,28 ± 0,33 D., and mean refractive cylinder was -0,53 ± 0,35 D.<br/>One hundred percent were within ± 1,00 D. and 95,09 % were within ± 0,50 D. of emmetropia at last examination.<br/>The refractions remained stable with a statistically insignificant change during follow-up.<br/>Uncorrected visual acuity improved in all cases. Best spectacle-corrected acuity remained the same or improved in all but two cases. Mean best spectacle-corrected acuity gain after the double procedure was two Snellen lines.<br/>Patient satisfaction with the final visual outcome was very high.<br/><br/>CONCLUSIONS: <br/>Combined posterior chamber phakic IOL implantation with ICLTM lens and Lasik (Bioptics) is an effective and reasonably predictable method for correcting high myopia. <br/>Gains in spectacle-corrected visual acuity were common, and results demonstrated good short-medium term safety and refractive stability.
eng
dc.format.mimetype
application/pdf
dc.language.iso
spa
dc.publisher
Universitat Autònoma de Barcelona
dc.rights.license
ADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.
dc.source
TDX (Tesis Doctorals en Xarxa)
dc.subject
Lentes faquicas
dc.subject
Cirugía oftalmológica
dc.subject
Defectos refractivos
dc.subject.other
Ciències de la Salut
dc.title
Uso de biópticos (ICL y Lasik) para la corrección de la alta miopía
dc.type
info:eu-repo/semantics/doctoralThesis
dc.type
info:eu-repo/semantics/publishedVersion
dc.subject.udc
617
cat
dc.contributor.director
García-Arumí, José
dc.contributor.director
Corcóstegui, Borja
dc.rights.accessLevel
info:eu-repo/semantics/openAccess
dc.identifier.dl
B-16346-2002


Documents

jjpg1de3.pdf

1.056Mb PDF

jjpg2de3.pdf

871.4Kb PDF

jjpg3de3.pdf

1.691Mb PDF

This item appears in the following Collection(s)