Design and application of nanomaterial-based lateral flow devices

dc.contributor
Universitat Autònoma de Barcelona. Departament de Química
dc.contributor.author
Quesada González, Daniel
dc.date.accessioned
2019-02-11T07:11:31Z
dc.date.available
2019-10-26T02:00:11Z
dc.date.issued
2018-10-26
dc.identifier.isbn
9788449083280
en_US
dc.identifier.uri
http://hdl.handle.net/10803/665602
dc.description.abstract
Els biosensors de fluxe lateral són dispositius basats en paper d'alta rellevància en diagnòstics "point-of-care" i monitoratge ambiental. Aquests dispositius són de baix cost, ràpids, robustos i simples de fer servir. En aquesta recerca, els dispositius de fluxe lateral són aplicats per la detecció d'ions d'urani en aigua potable amb alta sensibilitat i baix temps d'assaig. El límit de detecció obtingut amb aquest assaig ha estat 40 nM, tres vegades inferior a la quantitat màxima recomanada d'urani en aigües de consum. També, una nova estratègia per incrementar la senyal colorimètrica en les tires de fluxe lateral és reportada. Les nanofibres de cel·lulosa poden ésser introduïdes als nanoporus de la nitrocel·lulosa, matriu on les reaccions de fluxe lateral succeeixen, augmentant l'àrea on les biomolècules poden enganxar-se, incrementant així la probabilitat de retenir les partícules responsables del senyal en mostres positives. Seguint aquesta estratègia, s'ha aconseguit un increment del senyal colorimètric d'un 30%. I finalment, nanopartícules d'òxid d'iridi són reportades per primera vegada als assaigs de fluxe lateral com a senyalitzadors colorimètrics. Les propietats electroquímiques d'aquest nanomaterial permeten, a més d'una resposta òptica, la quantificació electroquímica de la mostra tal com s'ha demostrat detectant èters de difenil polibrominats aplicant nanopartícules d'òxid d'iridi en elèctrodes serigrafiats de carboni. La recerca bibliogràfica realitzada ha esdevingut en tres publicacions: • Quesada-González, D. & Merkoçi, A. “Nanoparticle-based lateral flow biosensors”. Biosens. Bioelectron. 73, 47–63 (2015). • Quesada-González, D. & Merkoçi, A. “Mobile phone–based biosensing: an emerging ‘diagnostic and communication’ technology”. Biosens. Bioelectron. 92, 549–562 (2016). • Quesada-González, D. & Merkoçi, A. “Nanomaterial-Based Devices for Point-of-Care Diagnostic Applications”. Chem. Soc. Rev. 47, 4697–4709 (2018). També el treball experimental ha esdevingut en 4 articles encara no publicats: • Quesada-González, D.; Jairo, G. A.; Blake, R.C., Blake, D.A. & Merkoçi, A. “Uranium (VI) detection in groundwater using a gold nanoparticle/paper-based lateral flow device”. Under revision (2018). • Quesada-González, D.; Stefani, C.; González, I.; de la Escosura-Muñiz, I.; Domingo, N.; Mutjé, P. & Merkoçi, A. “Signal enhancement on gold nanoparticle-based lateral flow tests using cellulose nanofibers”. In preparation (2018). • Quesada-González, D.; Baiocco, A.; Martos, A. A.; de la Escosura-Muñiz, A.; Palleschi, G. & Merkoçi, A. “Iridium oxide (IV) nanoparticle-based electrocatalytic detection of PBDE”. Under revision (2018). • Quesada-González, D.; Sena-Torralba, A.; Wicaksono, W. P.; de la Escosura-Muñiz, A.; Ivandini, T. A. & Merkoçi A. “Iridium oxide (IV) nanoparticle-based lateral flow immunoassay”. In preparation (2018).
en_US
dc.description.abstract
Lateral flow biosensors are paper-based devices of high relevance in point-of-care diagnostics and environmental monitoring. These devices are low-cost, fast, robust and simple to use. In this research, lateral flow biosensors are applied for the detection of uranium ions in drinking water with high selectivity and low assay time. The limit of detection reached in this assay was of 40 nM, three times lower than the maximum amount of uranium recommended in consume water. Also, a novel colorimetric signal enhancement strategy on lateral flow strips is reported. Cellulose nanofibers can be introduced into nitrocellulose pores, the matrix in which lateral flow reactions occur, increasing the area where biomolecules can be attached, increasing then the probability of stopping label particles on positive samples. Following this strategy, a 30% of color signal enhancement was achieved. And last, iridium oxide nanoparticles are reported for the first time on lateral flow assays as colorimetric labels. The electrocatalytical properties of this nanomaterial allow, besides the colorimetric response, electrochemical quantification of the sample as it is demonstrated by detecting polybrominated diphenyl ethers using iridium oxide nanoparticles on screen printed carbon electrodes. The state-of-the art studies carried out resulted in three review publications: • Quesada-González, D. & Merkoçi, A. “Nanoparticle-based lateral flow biosensors”. Biosens. Bioelectron. 73, 47–63 (2015). • Quesada-González, D. & Merkoçi, A. “Mobile phone–based biosensing: an emerging ‘diagnostic and communication’ technology”. Biosens. Bioelectron. 92, 549–562 (2016). • Quesada-González, D. & Merkoçi, A. “Nanomaterial-Based Devices for Point-of-Care Diagnostic Applications”. Chem. Soc. Rev. 47, 4697–4709 (2018). Also the experimental work performed conducted to four full length articles not yet published: • Quesada-González, D.; Jairo, G. A.; Blake, R.C., Blake, D.A. & Merkoçi, A. “Uranium (VI) detection in groundwater using a gold nanoparticle/paper-based lateral flow device”. Under revision (2018). • Quesada-González, D.; Stefani, C.; González, I.; de la Escosura-Muñiz, I.; Domingo, N.; Mutjé, P. & Merkoçi, A. “Signal enhancement on gold nanoparticle-based lateral flow tests using cellulose nanofibers”. In preparation (2018). • Quesada-González, D.; Baiocco, A.; Martos, A. A.; de la Escosura-Muñiz, A.; Palleschi, G. & Merkoçi, A. “Iridium oxide (IV) nanoparticle-based electrocatalytic detection of PBDE”. Under revision (2018). • Quesada-González, D.; Sena-Torralba, A.; Wicaksono, W. P.; de la Escosura-Muñiz, A.; Ivandini, T. A. & Merkoçi A. “Iridium oxide (IV) nanoparticle-based lateral flow immunoassay”. In preparation (2018).
en_US
dc.format.extent
226 p.
en_US
dc.format.mimetype
application/pdf
dc.language.iso
eng
en_US
dc.publisher
Universitat Autònoma de Barcelona
dc.rights.license
L'accés als continguts d'aquesta tesi queda condicionat a l'acceptació de les condicions d'ús establertes per la següent llicència Creative Commons: http://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rights.uri
http://creativecommons.org/licenses/by-nc-nd/4.0/
*
dc.source
TDX (Tesis Doctorals en Xarxa)
dc.subject
Biosensor
en_US
dc.subject
Nanotecnología
en_US
dc.subject
Nanoteecnologia
en_US
dc.subject
Nanotechnology
en_US
dc.subject
Fluxe lateral
en_US
dc.subject
Flujo lateral
en_US
dc.subject
Lateral flow
en_US
dc.subject.other
Ciències Experimentals
en_US
dc.title
Design and application of nanomaterial-based lateral flow devices
en_US
dc.type
info:eu-repo/semantics/doctoralThesis
dc.type
info:eu-repo/semantics/publishedVersion
dc.subject.udc
54
en_US
dc.contributor.authoremail
dquesada31@gmail.com
en_US
dc.contributor.director
Merkoçi, Arben
dc.embargo.terms
12 mesos
en_US
dc.rights.accessLevel
info:eu-repo/semantics/openAccess


Documents

dqg1de1.pdf

11.79Mb PDF

Aquest element apareix en la col·lecció o col·leccions següent(s)