Modelling the energy dynamics of ventilated photovoltaic facades using stochastic differential equations in a monitored Test Reference Environment

dc.contributor
Universitat de Lleida. Departament de Medi Ambient i Ciències del Sòl
dc.contributor.author
Lodi, Chiara
dc.date.accessioned
2012-10-01T13:00:36Z
dc.date.available
2013-07-10T05:45:04Z
dc.date.issued
2012-07-09
dc.identifier.uri
http://hdl.handle.net/10803/84167
dc.description.abstract
L'objectiu general d'aquest treball és contribuir a l'avaluació de la transferència de l'energia en règim dinàmic de sistemes Fotovoltaics de doble pell Integrats en Edificis (EIFV) amb ventilació forçada sota condicions climàtiques exteriors reals. Per tant, un dels objectius d'aquest treball de recerca va consistir a recol.lectar dades experimentals sota condicions externes reals amb el “Test Reference Environment” (TRE) al Parc Científic i Tecnològic Agroalimentari de Lleida (PCiTAL). Es va dur a terme una llarga campanya de mesures on es van realitzar diversos experiments, amb diferents inclinacions i règims de ventilació. Un altre objectiu va ser estimar paràmetres físics desconeguts mitjançant l'ús de models d'identificació. Per aconseguir aquest objectiu, diversos models de caixa grisa estocàstics es van desenvolupar. Finalment, a partir de l'experiència adquirida durant el treball experimental, d'anàlisi i de modelatge, s'ha proposat la definició d'un entorn de prova “Test Reference Environment” estandarditzat per a les aplicacions de EIFV de doble pell.
cat
dc.description.abstract
El objetivo general de este trabajo es contribuir a la evaluación de la transferencia de la energía en régimen dinámico de sistemas de doble piel FotoVoltaicos Integrados en Edificios (EIFV) con ventilación forzada bajo condiciones climáticas exteriores reales. Por lo tanto, uno de los objetivos de este trabajo de investigación consistió en recolectar datos experimentales bajo condiciones externas reales con el “Test Reference Environment” (TRE) en el Parque Científico y Tecnológico Agroalimentario de Lleida (PCiTAL). Se llevó a cabo una larga campaña de medidas donde se realizaron varios experimentos, con diferentes inclinaciones y regímenes de ventilación. Otro objetivo fue estimar parámetros físicos desconocidos mediante el uso de modelos de identificación. Para lograr este objetivo, varios modelos de caja gris estocásticos se desarrollaron. Por último, a partir de la experiencia adquirida durante el trabajo experimental, de análisis y de modelación, se ha propuesto la definición de un entorno de prueba “Test Reference Environment” estandarizado para las aplicaciones de EIFV de doble piel.
spa
dc.description.abstract
The general aim of this work is to contribute to the energy dynamics assessment of mechanically ventilated double skin Building Integrated PhotoVoltaic (BIPV) systems under real outdoor weather conditions. Therefore, one of the objectives of this research work has consisted in collecting experimental data under real outdoor conditions in the Test Reference Environment (TRE) at the Lleida Agri-food Science and Technology Park (PCiTal). An extensive monitoring campaign has been carried out and several experiments, at different inclinations and ventilation regimes, have been performed. Another goal was to estimate unknown physical parameters by using identification models. To achieve this goal, several stochastic grey-box models have been developed. Finally, from the experience gained during the experimental, analysis and modelling work, the definition of a standardized set-up for a Test Reference Environment for double skin applications of BIPV has been proposed.
eng
dc.format.extent
112 p.
dc.format.mimetype
application/pdf
dc.language.iso
eng
dc.publisher
Universitat de Lleida
dc.rights.license
L'accés als continguts d'aquesta tesi queda condicionat a l'acceptació de les condicions d'ús establertes per la següent llicència Creative Commons: http://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.rights.uri
http://creativecommons.org/licenses/by-nc-nd/3.0/es/
*
dc.source
TDX (Tesis Doctorals en Xarxa)
dc.subject
Façanes dobles
dc.subject
Edificis Integrats Fotovoltaics
dc.subject
Models de caixa grisa
dc.subject
Fachadas dobles
dc.subject
Edificios Integrados FotoVoltaicos
dc.subject
Modelos de caja gris
dc.subject
Double skin facades
dc.subject
Building Integrated PhotoVoltaic
dc.subject
Grey-box models
dc.subject.other
Física Aplicada
dc.title
Modelling the energy dynamics of ventilated photovoltaic facades using stochastic differential equations in a monitored Test Reference Environment
dc.type
info:eu-repo/semantics/doctoralThesis
dc.type
info:eu-repo/semantics/publishedVersion
dc.subject.udc
53
cat
dc.contributor.codirector
Rosell Urrutia, Joan Ignasi
dc.contributor.codirector
Chemisana Villegas, Daniel
dc.embargo.terms
12 mesos
dc.rights.accessLevel
info:eu-repo/semantics/openAccess
dc.identifier.dl
L-972-2012


Documentos

Tcl1de1.pdf

7.026Mb PDF

Este ítem aparece en la(s) siguiente(s) colección(ones)